This article describes how to configure a remote Sybari Antigen Client session in Microsoft Windows XP Service Pack 2 (SP2).
To configure a remote Antigen Client session in Windows XP SP2, follow these steps:
- On a computer that is running Windows XP SP2, click Start, click Run, type dcomcnfg, and then click OK.
- In the left pane, double-click Component Services, and then double-click Computers.
- In the right pane, right-click My Computer, and then click Properties.
- Click the DCOM Security tab, and then click Edit Limits under Access Permissions.
- Click Anonymous Logon, and then click to select the Allow check box for Remote Access.
- Click Start, click Control Panel, and then click Security Center.
- Click Windows Firewall, and then click the Exceptions tab.
- Click Add Program, click Sybari Client, and then click OK.
- Under Programs and Services, click to select the Sybari Client check box, and then click Add Port.
- In the Name box, type a name for the program.
- In the Port number box, type 135, make sure that the TCP option is selected, and then click OK.