Opening the Operations Manager 2007 console may result in an error message after upgrading to R2

Article ID: 971285 - View products that this article applies to.
Expand all | Collapse all
Source: Microsoft Support

RAPID PUBLISHING

RAPID PUBLISHING ARTICLES PROVIDE INFORMATION DIRECTLY FROM WITHIN THE MICROSOFT SUPPORT ORGANIZATION. THE INFORMATION CONTAINED HEREIN IS CREATED IN RESPONSE TO EMERGING OR UNIQUE TOPICS, OR IS INTENDED SUPPLEMENT OTHER KNOWLEDGE BASE INFORMATION.

Symptom



After System Center Operations Manager 2007 is upgraded to R2, the console may not load and may display the following error message:

Severity: Error

Message:

System.TypeLoadException: Could not load type 'Microsoft.EnterpriseManagement.ConsoleFramework.SettingsProviderAttribute' from assembly 'Microsoft.EnterpriseManagement.UI.ConsoleFramework, Version=6.0.4900.0, Culture=neutral, PublicKeyToken=31bf3856ad364e35'.

at System.ModuleHandle.ResolveType(Int32 typeToken, RuntimeTypeHandle* typeInstArgs, Int32 typeInstCount, RuntimeTypeHandle* methodInstArgs, Int32 methodInstCount)

at System.ModuleHandle.ResolveTypeHandle(Int32 typeToken, RuntimeTypeHandle[] typeInstantiationContext, RuntimeTypeHandle[] methodInstantiationContext)

at System.Reflection.Module.ResolveType(Int32 metadataToken, Type[] genericTypeArguments, Type[] genericMethodArguments)

at System.Reflection.CustomAttribute.FilterCustomAttributeRecord(CustomAttributeRecord caRecord, MetadataImport scope, Assembly& lastAptcaOkAssembly, Module decoratedModule, MetadataToken decoratedToken, RuntimeType attributeFilterType, Boolean mustBeInheritable, Object[] attributes, IList derivedAttributes, RuntimeType& attributeType, RuntimeMethodHandle& ctor, Boolean& ctorHasParameters, Boolean& isVarArg)

at System.Reflection.CustomAttribute.GetCustomAttributes(Module decoratedModule, Int32 decoratedMetadataToken, Int32 pcaCount, RuntimeType attributeFilterType, Boolean mustBeInheritable, IList derivedAttributes)

at System.Reflection.CustomAttribute.GetCustomAttributes(RuntimeType type, RuntimeType caType, Boolean inherit)

at System.ComponentModel.TypeDescriptor.CheckDefaultProvider(Type type)

at System.ComponentModel.TypeDescriptor.NodeFor(Type type, Boolean createDelegator)

at System.ComponentModel.TypeDescriptor.GetAttributes(Type componentType)

at Microsoft.EnterpriseManagement.Mom.Internal.UI.Console.MonitoringViewsNodeProvider.GetImage(String nodeImageKey)

at Microsoft.EnterpriseManagement.Mom.Internal.UI.Controls.AdvancedTreeView.LoadImageIntoImageList(ITreeImageProvider imageProvider, String imageKey)

at Microsoft.EnterpriseManagement.Mom.Internal.UI.Controls.AdvancedTreeView.Microsoft.EnterpriseManagement.Mom.Internal.UI.Controls.ITreeNodeImageList.LoadImagesIntoImageList(ITreeImageProvider imageProvider, ITreeNodeDefinition definition)

at Microsoft.EnterpriseManagement.Mom.Internal.UI.Controls.AdvancedTreeNode..ctor(AdvancedTreeView treeView, ITreeNodeDefinition definition, ITreeNodeImageList treeNodeImageList)

at Microsoft.EnterpriseManagement.Mom.Internal.UI.Controls.AdvancedTreeNode.AddMissingNodes(ICollection`1 nodes, Boolean autoExpandNode, Boolean force)

at Microsoft.EnterpriseManagement.Mom.Internal.UI.Controls.AdvancedTreeNode.SychronizeChildNodes(Boolean force)

at Microsoft.EnterpriseManagement.Mom.Internal.UI.Controls.AdvancedTreeView.CreateNodesFromDefinitions(ITreeNodeProvider treeNodeProvider)

at Microsoft.EnterpriseManagement.Mom.Internal.UI.Console.MonitoringPage.OnManagementGroupConnected(IManagementGroupSession mg)

at Microsoft.EnterpriseManagement.Mom.Internal.UI.Common.ManagementGroupServerSession.Connect(ManagementGroupConnectedDelegate handler)

at Microsoft.EnterpriseManagement.Mom.Internal.UI.Console.MonitoringPage.OnLoad(EventArgs e)

at Microsoft.EnterpriseManagement.Mom.Internal.UI.Console.MonitoringPage.OnCreateControl()

at System.Windows.Forms.Control.CreateControl(Boolean fIgnoreVisible)

at System.Windows.Forms.Control.CreateControl(Boolean fIgnoreVisible)

at System.Windows.Forms.Control.CreateControl()

at System.Windows.Forms.Control.ControlCollection.Add(Control value)

at Microsoft.EnterpriseManagement.ConsoleFramework.OutlookViewControl.ChangePage(Int32 index)

at Microsoft.EnterpriseManagement.ConsoleFramework.OutlookViewControl.OnPagesUpdated(Object sender, EventArgs e)

at Microsoft.EnterpriseManagement.ConsoleFramework.OutlookViewPageCollection.OnPagesUpdated()

at Microsoft.EnterpriseManagement.ConsoleFramework.NavigationPane.Microsoft.EnterpriseManagement.ConsoleFramework.IWunderbar.AddRange(ICollection`1 pageTypes, Int32 selectedPageIndex)

at Microsoft.EnterpriseManagement.Mom.Internal.UI.Console.MomConsoleWindow.AddWunderbarPages()

at Microsoft.EnterpriseManagement.Mom.Internal.UI.Console.ConsoleWindow.OnManagementGroupConnected(IManagementGroupSession session)

at Microsoft.EnterpriseManagement.Mom.Internal.UI.Common.ManagementGroupServerSession.Assign(IManagementGroupServerSession session)

at Microsoft.EnterpriseManagement.Mom.Internal.UI.Console.ConsoleWindowBase.ConnectToManagementGroupJob(Object sender, ConsoleJobEventArgs args)

at Microsoft.EnterpriseManagement.Mom.Internal.UI.Console.ConsoleJobExceptionHandler.ExecuteJob(IComponent component, EventHandler`1 job, Object sender, ConsoleJobEventArgs args)

Cause

This issue can occur if a third-party Management Pack that is not compatible with R2 is installed prior to the upgrade.

Resolution

Uninstall the Operations Manager 2007 version of the third-party product installed locally on this machine, then upgrade to Operations Manager 2007 R2 Operations Console and install the Operations Manager 2007 R2 version of the third-party product.

More Information



At this time Savision is known to experience this issue with some older Management Packs. For the latest version of the Savision Management Pack, visit the following Web site:

http://www.savision.com/download

The third-party products that this article discusses are manufactured by companies that are independent of Microsoft. Microsoft makes no warranty, implied or otherwise, about the performance or reliability of these products.

Microsoft provides third-party contact information to help you find technical support. This contact information may change without notice. Microsoft does not guarantee the accuracy of this third-party contact information.

DISCLAIMER

MICROSOFT AND/OR ITS SUPPLIERS MAKE NO REPRESENTATIONS OR WARRANTIES ABOUT THE SUITABILITY, RELIABILITY OR ACCURACY OF THE INFORMATION CONTAINED IN THE DOCUMENTS AND RELATED GRAPHICS PUBLISHED ON THIS WEBSITE (THE “MATERIALS”) FOR ANY PURPOSE. THE MATERIALS MAY INCLUDE TECHNICAL INACCURACIES OR TYPOGRAPHICAL ERRORS AND MAY BE REVISED AT ANY TIME WITHOUT NOTICE.

TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, MICROSOFT AND/OR ITS SUPPLIERS DISCLAIM AND EXCLUDE ALL REPRESENTATIONS, WARRANTIES, AND CONDITIONS WHETHER EXPRESS, IMPLIED OR STATUTORY, INCLUDING BUT NOT LIMITED TO REPRESENTATIONS, WARRANTIES, OR CONDITIONS OF TITLE, NON INFRINGEMENT, SATISFACTORY CONDITION OR QUALITY, MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WITH RESPECT TO THE MATERIALS.

Properties

Article ID: 971285 - Last Review: May 12, 2009 - Revision: 1.0
APPLIES TO
  • Microsoft System Center Operations Manager 2007
Keywords: 
kbrapidpub kbnomt KB971285

Give Feedback

 

Contact us for more help

Contact us for more help
Connect with Answer Desk for expert help.