Article ID: 169694 - Last Review: October 28, 2006 - Revision: 4.1 XCON: Content Conversion Fails When MDBEF Formatting Disabled over X.400 ConnectorThis article was previously published under Q169694 SYMPTOMS
The Microsoft Exchange message transfer agent (MTA) may fail to deliver
messages across an X.400 connector when MDBEF message transfer has been
disabled. Content conversion errors will be logged in the Exchange Server
computer's event log, and users will receive non-delivery reports (NDRs).
This problem will only occur with specific builds of the MTA when messages are sent over an X.400 Connector that is using metamorf conversion with MDBEF turned off. MDBEF is turned off by selecting the X.400 Connector's Advanced tab and clearing the check box for "Allow MS Exchange contents". STATUS
Microsoft has confirmed this to be a problem in Microsoft Exchange MTA
builds 996.31 and 996.32 for Exchange Server version 4.0. This problem has
been corrected in the latest U.S. Service Pack for Microsoft Exchange
Server version 4.0. For information on obtaining the Service Pack, query on
the following word in the Microsoft Knowledge Base (without the spaces):
S E R V P A C K
Microsoft has confirmed this to be a problem in Microsoft Exchange MTA builds 1459.17, 1459.18, 1459.19, 1459.20, 1459.21, 1459.22, and 1459.23 for Exchange Server version 5.0. This problem has been corrected in the latest U.S. Service Pack for Microsoft Exchange Server version 5.0. For information on obtaining the service pack, query on the following word in the Microsoft Knowledge Base (without the spaces):
S E R V P A C K
MORE INFORMATION
Users who encounter this problem will receive NDRs from the system
administrator with messages similar to the following:
Your message did not reach some or all of the intended recipients.
Subject:Test Message
Sent:8/1/97 2:02:00 PM
The following recipient(s) could not be reached:
John Doe on 8/1/97 2:02:10 PM
The message contains a content type that is not supported
MSEXCH:MSExchangeMTA:CPRWA:MARIAH
-or-
Your message did not reach some or all of the intended recipients.
Subject:Test Message
Sent:8/1/97 11:36:37 AM
The following recipient(s) could not be reached:
Kitty on 8/1/97 11:33:28 AM
A syntax error was detected in the content of the message
MSEXCH:MSExchangeMTA:Guitars:BRASS_KITTEN
Event ID:210 Source:MSExchangeMTA Type:Warning Category:X.400 Service Description: An internal MTA error occurred. Content conversion for message C=US;A= ;P=Microsoft;L=BRASS_KITTEN-970801221402Z-9376 failed. Conversion error: 4096, Object at fault: 0600003B, Original content type: 56010A01, New content type: 2A864886F7140501. PDU dump reference 4 [MTA DISP:FANOUT 16 112] (14) | Article Translations
|