Stop 0x0000002E Using Qlogic Driver Version 2.29

Article translations Article translations
Article ID: 193548 - View products that this article applies to.
This article was previously published under Q193548
This article has been archived. It is offered "as is" and will no longer be updated.
Expand all | Collapse all

SYMPTOMS

When you use a Qlogic SCSI adapter (with the Qlogic driver version 2.29) and you modify the NumberofRequests registry value to a number greater than the default of 128, the system generates the following blue screen error message:

STOP: 0x0000002E (0xFACEFEED, 0x00000000, 0x00000000, 0x80ADD9C8)
DATA_BUS_ERROR
NOTE: The four parameters inside the parentheses will vary according to the configuration of the system.

This value does not normally appear in the registry and must be added manually to change the default setting of 128.

RESOLUTION

To resolve this problem, obtain the latest service pack for Windows NT 4.0 or Windows NT Server 4.0, Terminal Server Edition. For additional information, click the following article number to view the article in the Microsoft Knowledge Base:
152734 How to Obtain the Latest Windows NT 4.0 Service Pack

STATUS

Microsoft has confirmed that this is a problem in Windows NT 4.0 and Windows NT Server 4.0, Terminal Server Edition. This problem was first corrected in Windows NT 4.0 Service Pack 4.0 and Windows NT Server 4.0, Terminal Server Edition Service Pack 4.

Properties

Article ID: 193548 - Last Review: October 10, 2013 - Revision: 2.1
APPLIES TO
  • Microsoft Windows NT Server 4.0, Terminal Server Edition
  • Microsoft Windows NT Workstation 4.0 Developer Edition
  • Microsoft Windows NT Server 4.0 Standard Edition
Keywords: 
kbnosurvey kbarchive kbbug kbfix KB193548

Give Feedback

 

Contact us for more help

Contact us for more help
Connect with Answer Desk for expert help.
Get more support from smallbusiness.support.microsoft.com