Article ID: 219008 - Last Review: January 24, 2007 - Revision: 1.1 Remedy Help Desk Notifier Causes GP Fault in Module Tirpc.dllThis article was previously published under Q219008 SYMPTOMS
When you start the Notifier tool included with Remedy Help Desk after you upgrade to Internet Explorer 5, you may receive the following error message:
NOTIFIER caused a general protection fault in module TIRPC.DLL at 0001:00004a94.
CAUSE
This error message is caused by an increase in the amount of stack space used by Wininet.dll in Internet Explorer 5. Because Notifier is a 16-bit Windows-based program, it cannot account for this additional stack space usage. This causes a stack overflow.
RESOLUTION
To resolve this issue, add a "NOTIFIER=0x400000" line to the [Compatibility] section of the Win.ini file:
The third-party products that are discussed in this article are manufactured by companies that are independent of Microsoft. Microsoft makes no warranty, implied or otherwise, regarding the performance or reliability of these products. | Article Translations
|