Article ID: 230288 - Last Review: October 28, 2006 - Revision: 3.3 XFOR: NDR from Internet Mail Service Contains Incorrect 3-Byte Reason Code Sent to X.400 ConnectorThis article was previously published under Q230288 SYMPTOMS
Microsoft Exchange Message Transfer Agent (MTA) transfers a NonDeliveryReasonCode of 3-byte integer. The field is defined in X.411 specifications as a 1 byte integer. Some X.400 MTAs cannot handle the extra bytes and may stop processing information. CAUSE
The NonDeliveryReasonCode being passed is incorrectly set to -1, which is not a valid code.
RESOLUTIONTo resolve this problem, obtain the latest service pack for Exchange Server version 5.5. For additional information, click the following article number to view the article in the
Microsoft Knowledge Base:
191014
(http://support.microsoft.com/kb/191014/EN-US/
)
XGEN: How to Obtain the Latest Exchange Server 5.5 Service Pack
The English version of this fix should have the following file attributes or later:Component: Internet Mail Service Collapse this table
STATUSMicrosoft has confirmed that this is a problem in Microsoft Exchange Server version 5.5. This problem was first corrected in Exchange Server 5.5 Service Pack 3. | Article Translations
|

Back to the top