Microsoft로 로그인
로그인하거나 계정을 만듭니다.
안녕하세요.
다른 계정을 선택합니다.
계정이 여러 개 있음
로그인할 계정을 선택합니다.
영어
죄송합니다. 이 문서는 귀하의 언어로 사용할 수 없습니다.

Symptoms

Consider the following scenario:

  • You run a BizTalk application that uses a WCF-WSHttp send port in Microsoft BizTalk Server 2009.

  • The send port uses a custom send pipeline.

  • The custom send pipeline component of the send pipeline uses Messaging Event Streams to receive tracking data.

  • You deploy a Business Activity Monitoring (BAM) activity.

  • You apply a BAM activity definition-based tracking profile.

  • The BizTalk application processes a message.

In this scenario, the BAM activity data is not written. Additionally, the records in the BAMPrimaryImport database are not moved from the BAM_<Activity_Name>_Active table to the BAM_<Activity_Name>_Completed table.

Resolution

Cumulative update information

The hotfix that resolves this issue is included in Cumulative Update 1 for BizTalk Server 2009. 

For more information about how to obtain the cumulative update package, click the following article number to view the article in the Microsoft Knowledge Base:

2429050 Cumulative update package 1 for BizTalk Server 2009

Hotfix information

A supported hotfix is available from Microsoft. However, this hotfix is intended to correct only the problem that is described in this article. Apply this hotfix only to systems that are experiencing this specific problem.

If the hotfix is available for download, there is a "Hotfix download available" section at the top of this Knowledge Base article. If this section does not appear, submit a request to Microsoft Customer Service and Support to obtain the hotfix.

Note If additional issues occur or if any troubleshooting is required, you might have to create a separate service request. The usual support costs will apply to additional support questions and issues that do not qualify for this specific hotfix. For a complete list of Microsoft Customer Service and Support telephone numbers or to create a separate service request, visit the following Microsoft website:

http://support.microsoft.com/contactus/?ws=supportNote The "Hotfix download available" form displays the languages for which the hotfix is available. If you do not see your language, it is because a hotfix is not available for that language.



Prerequisites

To apply this hotfix, you must have Microsoft BizTalk Server 2009 installed.

Restart requirement

You do not have to restart the computer after you apply this hotfix. However, you must restart the instance of BizTalk Host after you apply this hotfix.

Hotfix replacement information

This hotfix does not replace any other hotfix.

File Information



The English version of this hotfix has the file attributes (or later file attributes) that are listed in the following table. The dates and times for these files are listed in Coordinated Universal Time (UTC). When you view the file information, it is converted to local time. To find the difference between UTC and local time, use the Time Zone tab in the Date and Time item in Control Panel.

For all supported 32-bit versions of BizTalk Server 2009



File name

File version

File size

Date

Time

Platform

Btsmsgcore.dll

3.8.433.2

1,247,576

20-Jul-2010

13:51

x86

For all supported 64-bit versions of BizTalk Server 2009



File name

File version

File size

Date

Time

Platform

Btsmsgcore.dll

3.8.433.2

1,976,152

20-Jul-2010

17:23

x64

Workaround

To work around this issue, use the following configuration:

  • Use a send port that uses the WCF-Custom adapter.

  • Use the wsHttpBinding binding type for the port.

  • Click to select the Use Transaction check box, and then set the Isolation Level list to ReadCommitted.


Status

Microsoft has confirmed that this is a problem in the Microsoft products that are listed in the "Applies to" section.

More Information

For more information about Messaging Event Streams, visit the following Microsoft Development Network (MSDN) website:

General information about Messaging Event Streams
For more information about IPipelineContext.GetEventStream method, visit the following MSDN website:

General information about PipelineContext.GetEventStream method
For more information about how to use BAM, visit the following Microsoft TechNet website:

How to use BAM
For more information about BizTalk Server hotfixes, click the following article number to view the article in the Microsoft Knowledge Base:

2003907 Information on BizTalk Server hotfixes
For more information about how to configure a WCF-WSHttp send port, visit the following MSDN website:

How to configure a WCF-WSHttp send port

도움이 더 필요하세요?

더 많은 옵션을 원하세요?

Explore subscription benefits, browse training courses, learn how to secure your device, and more.

Communities help you ask and answer questions, give feedback, and hear from experts with rich knowledge.

이 정보가 유용한가요?

사용 경험에 어떠한 영향을 주었나요?
제출을 누르면 피드백이 Microsoft 제품과 서비스를 개선하는 데 사용됩니다. IT 관리자는 이 데이터를 수집할 수 있습니다. 개인정보처리방침

의견 주셔서 감사합니다!

×