Article ID: 236949 - Last Review: November 1, 2006 - Revision: 2.3 Improper Shutdown Occurrence Is Reported in the Event Viewer System LogThis article was previously published under Q236949 IMPORTANT: This article contains information about modifying the registry. Before you
modify the registry, make sure to back it up and make sure that you understand how to restore
the registry if a problem occurs. For information about how to back up, restore, and edit the
registry, click the following article number to view the article in the Microsoft Knowledge Base:
256986
(http://support.microsoft.com/kb/256986/EN-US/
)
Description of the Microsoft Windows Registry
On This PageSYMPTOMS
When you restart a computer running Windows NT after it has been
shutdown using a utility (such as Shutdown.exe from the Windows
NT resource kit) or method that calls the InitiateSystemShutdown()
API (for example, remote shutdown), the following error message may
appear in the Windows NT Event Viewer System log file:
Event ID: 6008 Source: Event Log Description: The previous system shutdown at time on date was unexpected. CAUSE
A remote shutdown issue using the InitiateSystemShutdown()
API call was fixed in Windows NT 4.0 Service Pack 4. This fix
introduced the symptom listed in this article.
RESOLUTIONWindows NT Server or Workstation 4.0To resolve this problem, obtain the latest service pack for Windows NT 4.0 or the individual software update. For information on obtaining the latest service pack, please go to:
http://support.microsoft.com/default.aspx?scid=fh;EN-US;CNTACTMS
(http://support.microsoft.com/default.aspx?scid=fh;en-us;cntactms)
Windows NT Server 4.0, Terminal Server EditionTo resolve this problem, obtain the latest service pack for Windows NT Server 4.0, Terminal Server Edition. For additional information, click the following article number to view the article in the Microsoft Knowledge Base:152734
(http://support.microsoft.com/kb/152734/EN-US/
)
How to Obtain the Latest Windows NT 4.0 Service Pack
STATUSMicrosoft has confirmed that this is a problem in Windows NT 4.0 and Windows NT Server 4.0, Terminal Server Edition. This problem was first corrected in Windows NT Server 4.0 Service Pack 6 and Windows NT Server 4.0, Terminal Server Edition Service Pack 6. MORE INFORMATIONWARNING: If you use Registry Editor incorrectly, you may cause serious problems that may
require you to reinstall your operating system. Microsoft cannot guarantee that you can solve
problems that result from using Registry Editor incorrectly. Use Registry Editor at your own
risk. To prevent the improper shutdown event entry from being written to the Event Viewer system log:
APPLIES TO
| Article Translations
|
Back to the top