Microsoft hesabıyla oturum açın
Oturum açın veya hesap oluşturun.
Merhaba,
Farklı bir hesap seçin.
Birden çok hesabınız var
Oturum açmak istediğiniz hesabı seçin.
İngilizce
Ne yazık ki bu makale dilinizde sunulmuyor.

Symptoms

Consider the following scenario:

  • You have a computer that is running a 64-bit version of Commerce Server 2009 or of Commerce Server 2007.

  • You open Total.pcf in the 64-bit edition of the Commerce Server Pipeline Editor. You check the properties page of the Commerce Splitter pipeline component to make sure it contains configuration data.

  • You insert a Commerce Scriptor, or Commerce StepwiseShipping pipeline component, or any 64-bit Commerce Server pipeline component after the Commerce Splitter pipeline component.

  • You save the pipeline configuration file (pcf) and then you close Pipeline Editor.

  • You open the Total.pcf again in Pipeline Editor.

In this scenario, you find that the configuration data for the Commerce Splitter pipeline component is missing when you check the component property.

When this problem occurs, if you execute later pipelines in Total.pcf, you receive an error message that resembles the following:

Type : System.Runtime.InteropServices.COMException, mscorlib, Version=2.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089

Message : Component Execution failed for component[0x1] hr: 0x1DE4A430

ProgID: Commerce.ShippingMethodRouter.1

Dictionary error: Value for key 'shipping_method_id' in dictionary '' missing (expected a variant of type 8)

Source : Commerce.MtsPipeline


Note You cannot resolve this issue even after you add back the configuration data back into the Commerce Splitter pipeline component.

Resolution

More information about this hotfix

To resolve this issue, install this hotfix, and then, you must create a new total.pcf file. To do this, follow these steps:

  1. To create a new Total.pcf file, you must open a Total.pcf that was never changed by using the 64-bit edition of the Commerce Server Pipeline Editor. You can add the desired 64-bit pipeline components into the Total.pcf file.

  2. Replace the old Total.pcf files by using the newly created Total.pcf file.

  3. Restart Internet Information Services (IIS) for the change to take effect. To restart IIS, at a command prompt, type the following command, and then press ENTER:

    iisreset /restart Note This option stops all IIS services that are running and then restarts them.


Hotfix information

A supported hotfix is available from Microsoft. However, this hotfix is intended to correct only the problem that is described in this article. Apply this hotfix only to systems that are experiencing the problem described in this article. This hotfix might receive additional testing. Therefore, if you are not severely affected by this problem, we recommend that you wait for the next software update that contains this hotfix.

If the hotfix is available for download, there is a "Hotfix download available" section at the top of this Knowledge Base article. If this section does not appear, contact Microsoft Customer Service and Support to obtain the hotfix.

Note If additional issues occur or if any troubleshooting is required, you might have to create a separate service request. The usual support costs will apply to additional support questions and issues that do not qualify for this specific hotfix. For a complete list of Microsoft Customer Service and Support telephone numbers or to create a separate service request, visit the following Microsoft website:

http://support.microsoft.com/contactus/?ws=supportNote The "Hotfix download available" form displays the languages for which the hotfix is available. If you do not see your language, it is because a hotfix is not available for that language.

Prerequisites

You must have Commerce Server 2007 Service Pack 2 or Commerce Server 2009 installed to apply this hotfix.

Restart requirement

You do not have to restart the computer after you apply this hotfix package.

Hotfix replacement information

This hotfix package does not replace a previously released hotfix package.

File Information

The English (United States) version of this hotfix uses a Microsoft Windows Installer package to install the hotfix. The dates and the times for these files are listed in Coordinated Universal Time (UTC) in the following table. When you view the file information, the date is converted to local time. To find the difference between UTC and local time, use the Time Zone tab in the Date and Time item in Control Panel.

Commerce Server 2007 Service Pack 2

File name

File version

File size

Date

Time

Platform

Stdretcomp.dll

6.0.4109.58

415,496

18-Mar-2011

08:33

x64

Stdretcomp.dll

6.0.4109.58

233,224

18-Mar-2011

08:33

x86

Commerce Server 2009

File name

File version

File size

Date

Time

Platform

Cs2009hotfixhelper.exe

6.0.4171.17

12,136

01-Sep-2010

13:37

x86

Stdretcomp.dll

6.0.4171.29

233,224

27-Sep-2010

13:01

x86

Stdretcomp.dll

6.0.4171.29

415,496

27-Sep-2010

13:01

x64

Status

Microsoft has confirmed that this is a problem in the Microsoft products that are listed in the "Applies to" section.

More Information

For more information about configuring and running a pipeline in Commerce Server 2009, visit the following MSDN websites:

How to run a Commerce Server Pipeline

How to view and modify Pipeline Properties

Daha fazla yardıma mı ihtiyacınız var?

Daha fazla seçenek mi istiyorsunuz?

Explore subscription benefits, browse training courses, learn how to secure your device, and more.

Communities help you ask and answer questions, give feedback, and hear from experts with rich knowledge.

Bu bilgi yararlı oldu mu?

Deneyiminizi ne etkiledi?
Gönder’e bastığınızda, geri bildiriminiz Microsoft ürün ve hizmetlerini geliştirmek için kullanılır. BT yöneticiniz bu verileri toplayabilecek. Gizlilik Bildirimi.

Geri bildiriminiz için teşekkürler!

×