Cluster Does Not Log Event on Resource Monitor Failure

Article translations Article translations
Article ID: 242386
This article was previously published under Q242386
Expand all | Collapse all

On This Page

SYMPTOMS

If a resource monitor stops working, Failover Manager (FM) generates a new one and resources are brought back online. When this occurs, nothing is logged in the Event log to indicate the failed resource monitor or the related failed resources.

RESOLUTION

Windows NT Server, Cluster Server, or Workstation 4.0

To resolve this problem, obtain the latest service pack for Windows NT 4.0 or the individual software update. For information on obtaining the latest service pack, please go to:
  • Windows Service Pack Center -or-

  • 152734how to obtain the latest windows nt 4.0 service pack
For information on obtaining the individual software update, contact Microsoft Product Support Services. For a complete list of Microsoft Product Support Services phone numbers and information on support costs, please go to the following address on the World Wide Web:
http://support.microsoft.com/default.aspx?scid=fh;EN-US;CNTACTMS


Windows NT Server 4.0, Terminal Server Edition

To resolve this problem, obtain the latest service pack for Windows NT Server 4.0, Terminal Server Edition. For additional information, click the following article number to view the article in the Microsoft Knowledge Base:
152734 How to Obtain the Latest Windows NT 4.0 Service Pack

STATUS

Microsoft has confirmed that this is a problem in Windows NT 4.0 Cluster Server. This problem was first corrected in Windows NT Server version 4.0, Terminal Server Edition Service Pack 6.