Article ID: 2424582 - Last Review: December 20, 2010 - Revision: 3.1
The onKillFocus event is not fired when you move the input focus in an Adobe Flash Lite ActiveX Control-based application on a Windows Embedded CE 6.0 R3-based OS design image
System TipThis article applies to a different operating system than the one you are using. Article content that may not be relevant to you is disabled.
You create an image of a Windows Embedded CE 6.0 R3-based OS design. This OS design includes the Adobe Flash Lite ActiveX Control (SYSGEN_IE_FLASHLITE) component for a target device.
You run an Adobe Flash application on the image.
You set the input focus to an element.
You click or tap elsewhere on the UI of the application, and the input focus moves away from the element.
In this scenario, the onKillFocus event for the element is not fired. Additionally, the performance of the application becomes poor.
A supported software update is now available from Microsoft as Windows Embedded CE 6.0 Platform Builder Monthly Update (November 2010). You can confirm this by scrolling to the "File information" section. The package file name contains the product version, date, Knowledge Base article number, and processor type. The package file name format is as follows:
Product version-yymmdd-kbnnnnnn-processor type
For example: Wincepb50-060503-kb917590-armv4i.msi is the ARMV4i Windows CE 5.0 Platform Builder fix that is documented in KB article 917590 and that is contained in the May 2006 monthly update. To resolve this problem immediately, click the following article number for information about how to obtain Windows CE Platform Builder and core operating system software updates:
837392
(http://support.microsoft.com/kb/837392/
)
How to locate core operating system fixes for Microsoft Windows CE Platform Builder products
Prerequisites
This software update is supported only if all previously issued software updates for this product have also been applied.
Restart requirement
After you install this software update, you must perform a clean build of the whole platform. To do this, use one of the following methods:
On the Build menu, click Clean Solution, and then click Build Solution.
On the Build menu, click Rebuild Solution.
You do not have to restart the computer after you apply this software update.
Update replacement information
This update does not replace any updates.
File information
The English version of this software update package has the file attributes (or later file attributes) that are listed in the following table. The dates and times for these files are listed in Coordinated Universal Time (UTC). When you view the file information, it is converted to local time. To find the difference between UTC and local time, use the Time Zone tab in the Date and Time item in Control Panel.