Article ID: 2556378 - Last Review: July 13, 2011 - Revision: 2.0

FIX: Issues occur with the IOCTL_SERVICE_STOP, the IOCTL_SERVICE_START, and the HCI vendor specific commands for the Bluetooth functionality in Windows Embedded CE 6.0 R3

System TipThis article applies to a different operating system than the one you are using. Article content that may not be relevant to you is disabled.

On This Page

Expand all | Collapse all

SYMPTOMS

When you use a Windows Embedded CE 6.0 R3-based image that enables Bluetooth functionality, you may experience one of the following issues:
  • When the Host Controller Interface (HCI) for the Bluetooth stack has to process the vendor-specific command (0x3F) and the vendor-specific event (0xFF), the stack shuts down unexpectedly.
  • When the input parameter of the IOCTL_SERVICE_START is empty, the Bluetooth service does not start as expected, even though IOCTL_SERVICE_START is returned successfully.
  • When the input parameter of the IOCTL_SERVICE_STOP is empty, the Bluetooth service does not stop as expected.

CAUSE

These issues occur for one of the following reasons:
  • A conflicted implementation occurs for the 0xFF event on the Bluetooth stack.
  • When you restart the Bluetooth server, a call to reset the SVSThreadpool interface is missed.
  • An incorrect sequencing of the Bluetooth service shutdown occurs, and this incorrect sequencing causes the Bluetooth service to stop responding. 

RESOLUTION

Software update information

A supported software update is now available from Microsoft as Windows Embedded CE 6.0 Monthly Update June, 2011. In the "File information" section, the package file name contains the product version, date, Knowledge Base article number, and processor type. The package file name format is as follows:
Product version-yymmdd-kbnnnnnn-processor type
For example: Wincepb60-110128-kb2492159-armv4i.msi is the ARMV4i Windows Embedded CE 6.0 Platform Builder fix that is documented in KB article 2492159 and that is contained in the January 2011 monthly update.

To resolve this problem immediately, download this Windows Embedded CE 6.0 Monthly Update from one of the following Microsoft websites:

Windows Embedded
Download Windows Embedded CE 6.0 (http://www.microsoft.com/windowsembedded/en-us/downloads/download-windows-embedded-ce6.aspx)
Microsoft Download Center
Windows Embedded CE 6.0 (http://www.microsoft.com/downloads/en/ResultsForProduct.aspx?productID=f8af6708-edcb-472a-829d-f73d951c35a1&stype=ss_sd&displaylang=en&nr=10&sortCriteria=Popularity&sortOrder=Ascending)

Prerequisites

This update is supported only if all previously issued updates for this product have also been installed.

Restart requirement

After you apply this update, you must perform a clean build of the whole platform. To do this, use one of the following methods:
  • On the Build menu, click Clean Solution, and then click Build Solution.
  • On the Build menu, click Rebuild Solution.
You do not have to restart the computer after you apply this software update.

Update replacement information

This update does not replace any other updates.

File information

The English version of this software update package has the file attributes (or later file attributes) that are listed in the following table. The dates and times for these files are listed in Coordinated Universal Time (UTC). When you view the file information, it is converted to local time. To find the difference between UTC and local time, use the Time Zone tab in the Date and Time item in Control Panel.
Installer files
Collapse this tableExpand this table
File nameFile sizeDateTime
Wincepb60-110622-kb2556378-armv4i.msi1,325,05623-Jun-201115:32
Wincepb60-110622-kb2556378-mipsii.msi1,300,99223-Jun-201115:32
Wincepb60-110622-kb2556378-mipsii_fp.msi1,301,50423-Jun-201115:32
Wincepb60-110622-kb2556378-mipsiv.msi1,304,06423-Jun-201115:32
Wincepb60-110622-kb2556378-mipsiv_fp.msi1,304,57623-Jun-201115:32
Wincepb60-110622-kb2556378-sh4.msi1,274,88023-Jun-201115:32
Wincepb60-110622-kb2556378-x86.msi1,190,40023-Jun-201115:32
Files that are included in this update package
Collapse this tableExpand this table
File nameFile sizeDateTimePath
Windows embedded ce 6.0_update_kb2556378.htm7,97322-Jun-201123:00110622_kb2556378
Hci.cxx323,70514-Jun-201120:11Private\Winceos\Comm\Bluetooth\Hci\Base
Btutils.cxx12,38714-Jun-201120:11Private\Winceos\Comm\Bluetooth\Sys
Bt_ddi.h108,89014-Jun-201120:11Public\Common\Oak\Inc
Bthci.lib874,59014-Jun-201120:10Public\Common\Oak\Lib\Armv4i\Debug
Btsysd.lib1,009,29814-Jun-201120:10Public\Common\Oak\Lib\Armv4i\Debug
Bthci.lib358,13014-Jun-201120:10Public\Common\Oak\Lib\Armv4i\Retail
Btsysd.lib518,05814-Jun-201120:09Public\Common\Oak\Lib\Armv4i\Retail
Bthci.lib849,25814-Jun-201120:10Public\Common\Oak\Lib\Mipsii\Debug
Btsysd.lib990,86214-Jun-201120:10Public\Common\Oak\Lib\Mipsii\Debug
Bthci.lib346,01014-Jun-201120:10Public\Common\Oak\Lib\Mipsii\Retail
Btsysd.lib514,31814-Jun-201120:10Public\Common\Oak\Lib\Mipsii\Retail
Bthci.lib849,26414-Jun-201120:10Public\Common\Oak\Lib\Mipsii_fp\Debug
Btsysd.lib990,83014-Jun-201120:10Public\Common\Oak\Lib\Mipsii_fp\Debug
Bthci.lib346,01814-Jun-201120:10Public\Common\Oak\Lib\Mipsii_fp\Retail
Btsysd.lib514,36014-Jun-201120:10Public\Common\Oak\Lib\Mipsii_fp\Retail
Bthci.lib858,38614-Jun-201120:10Public\Common\Oak\Lib\Mipsiv\Debug
Btsysd.lib1,003,20414-Jun-201120:10Public\Common\Oak\Lib\Mipsiv\Debug
Bthci.lib349,61614-Jun-201120:10Public\Common\Oak\Lib\Mipsiv\Retail
Btsysd.lib515,66214-Jun-201120:10Public\Common\Oak\Lib\Mipsiv\Retail
Bthci.lib858,39214-Jun-201120:10Public\Common\Oak\Lib\Mipsiv_fp\Debug
Btsysd.lib1,003,16214-Jun-201120:10Public\Common\Oak\Lib\Mipsiv_fp\Debug
Bthci.lib349,62414-Jun-201120:10Public\Common\Oak\Lib\Mipsiv_fp\Retail
Btsysd.lib515,70414-Jun-201120:10Public\Common\Oak\Lib\Mipsiv_fp\Retail
Bthci.lib757,86014-Jun-201120:11Public\Common\Oak\Lib\Sh4\Debug
Btsysd.lib875,80414-Jun-201120:11Public\Common\Oak\Lib\Sh4\Debug
Bthci.lib305,06814-Jun-201120:11Public\Common\Oak\Lib\Sh4\Retail
Btsysd.lib459,23414-Jun-201120:11Public\Common\Oak\Lib\Sh4\Retail
Bthci.lib741,57014-Jun-201120:09Public\Common\Oak\Lib\X86\Debug
Btsysd.lib843,94214-Jun-201120:09Public\Common\Oak\Lib\X86\Debug
Bthci.lib267,75014-Jun-201120:09Public\Common\Oak\Lib\X86\Retail
Btsysd.lib416,39614-Jun-201120:09Public\Common\Oak\Lib\X86\Retail

REFERENCES

For more information about software update terminology, click the following article number to view the article in the Microsoft Knowledge Base:
824684  (http://support.microsoft.com/kb/824684/ ) Description of the standard terminology that is used to describe Microsoft software updates

APPLIES TO
  • Windows Embedded CE 6.0 R3
Keywords: 