Article ID: 258189 - Last Review: November 21, 2006 - Revision: 2.1 IIS Log Contains Wrong Data When ISAPI Uses Default for File Size
This article was previously published under Q258189 SYMPTOMS
When an ISAPI application uses the HSE_TF_INFO data structure to issue a ServerSupportFunction(HSE_REQ_TRANSMIT_FILE), it is allowed to specify 0 as the value of the HSE_TF_INFO::BytesToWrite meaning, "send all file."
If zero is specified, then the sc-bytes value in the Internet Information Services (IIS) log file is invalid, because it reflects only the headers and not the entire transfer size.
CAUSE
IIS does not log the total size of the file that is actually transferred,
but uses the size argument transmitted to the TransmitFile API.
RESOLUTIONTo resolve this problem, obtain the latest service pack for Windows 2000. For additional information, click the following article number to view the article in the
Microsoft Knowledge Base:
260910
(http://support.microsoft.com/kb/260910/EN-US/
)
How to Obtain the Latest Windows 2000 Service Pack
STATUSMicrosoft has confirmed that this is a problem in Internet Information Services 5.0. This problem was first corrected in Windows 2000 Service Pack 1. MORE INFORMATION
The symptoms may be different in IIS 4.0. For additional information, click the article number below
to view the article in the Microsoft Knowledge Base:
248819
(http://support.microsoft.com/kb/248819/EN-US/
)
IIS 4.0 Logs Incorrect Values for Bytes Sent Field in W3C Extended Log
| Other Resources Other Support Sites