A System Center Virtual Machine Manager 2008 P2V fails at 79% with Error 551

Article ID: 2616508 - View products that this article applies to.
Expand all | Collapse all

Symptoms

A P2V conversion using System Center Virtual Machine Manager 2008 R2 (VMM 2008) fails at 79% completion with Error 551.  The details reveal the information below:

VMM cannot access registry key value NetCfgInstanceId under HKEY_LOCAL_MACHINE\vmm{GUID}system\ControlSet001\Control\Class\{GUID}\0043. 
 (The system cannot find the file specified (0x80070002))

Cause

This can occur when there is a ghosted network adapter on the P2V source machine.

Resolution

To resolve this issue, follow the steps outlined in the following KB article to remove any ghosted NICs on the source machine:

269155 - Error message when you try to set an IP address on a network adapter

Note This is a "FAST PUBLISH" article created directly from within the Microsoft support organization. The information contained herein is provided as-is in response to emerging issues. As a result of the speed in making it available, the materials may include typographical errors and may be revised at any time without notice. See Terms of Use for other considerations.

Properties

Article ID: 2616508 - Last Review: September 12, 2011 - Revision: 2.0
APPLIES TO
  • Microsoft System Center Virtual Machine Manager 2008
  • Microsoft System Center Virtual Machine Manager 2008 R2 Workgroup Edition
  • Microsoft System Center Virtual Machine Manager 2008 Workgroup Edition