Article ID: 275647 - Last Review: October 26, 2006 - Revision: 3.1 XCON: MTA Stops Unexpectedly in GwartCopyDoorwayList()This article was previously published under Q275647 SYMPTOMS
The Exchange Server version 5.5 Service Pack (SP3) message transfer agent (MTA) may stop unexpectedly with a call stack similar to the following:
FramePtr RetAddr Param1 Param2 Param3 Function Name 061acccc 004dda19 03036309 061ad91c 02e85dfc EMSMTA!GwartCopyDoorwayList+0x55 061ad928 00537d42 02e85dfc 02e8287c 061af694 EMSMTA!otpmrgwy+0x649 061afc58 004f1c8b 02e82874 00000006 02e82874 EMSMTA!orprmtsr+0xe82 061afc74 004ef337 00554a17 02e82874 02e80002 EMSMTA!otpmrout+0xab 061afee8 004ed0b1 00554a17 00000000 00000001 EMSMTA!otpmrd+0x2b7 061aff4c 004ea07a 00554a17 000041e8 00000398 EMSMTA!otpmrcd+0x6b1 061aff8c 00554ac8 000041e8 02e82705 00000017 EMSMTA!otpmmain+0x38a 061affb8 77f04ee8 00000017 000041e8 02e82705 EMSMTA!sbpiwbep+0x58
Event ID: 9405 An unexpected error has occurred which may cause the MTA to terminate. Error: Releasing unowned write lock 5589271. [BASE DISP:ROUTER 23] (16) Event ID: 9405 An unexpected error has occurred which may cause the MTA to terminate. Error: Access violation (0xc0000005) at Address 0x49863e reading from 0x45495049. [BASE DISP:ROUTER 14] (16) RESOLUTIONTo resolve this problem, obtain the latest service pack for Exchange Server 5.5. For additional information, click the following article number to view the article in the
Microsoft Knowledge Base:
191014
(http://support.microsoft.com/kb/191014/EN-US/
)
XGEN: How to Obtain the Latest Exchange Server 5.5 Service Pack
WORKAROUND
If you run MTACheck several times, it may allow the MTA to restart.
STATUSMicrosoft has confirmed that this is a problem in the Microsoft products that are listed at the beginning of this article. This problem was first corrected in Exchange Server 5.5 Service Pack 4. | Article Translations
|

Back to the top