FIX: Dump file isn't generated correctly when a dump file is larger than 62 KB in Windows Embedded CE 6.0 R3

Article translations Article translations
Article ID: 2826750 - View products that this article applies to.
Expand all | Collapse all

On This Page

Symptoms

Consider the following scenario:
  • You create a Windows Embedded CE 6.0 R3-based run-time image that includes the following Error Reporting Catalog Items:
    • SYSGEN_WATSON_CLIENT
    • SYSGEN_WATSON_CLIENT_UI
    • SYSGEN_WATSON_CTLPNL
    • SYSGEN_WATSON_DMPGEN
    • SYSGEN_WATSON_XFER

  • You run the image on a device.
  • A crash occurs in an application that is running on the device.
  • You check the crash dump file.
In this scenario, the dump file generator does not generate the dump file correctly. 

Notes

  • This issue occurs when the dump file to be generated is larger than 62 kilobytes (KB).
  • Only a mini-dump file that does not contain call stack information is generated.

Resolution

After you apply the fix, the size restriction on Error Reporting context dump buffer is removed.

Software update information

Download information

A supported software update is now available from Microsoft. This update is named "Windows Embedded CE 6.0 Monthly Update March 2013."

The product version, date, Microsoft Knowledge Base article number, and processor type that each update package corresponds to are contained in the package file names that are listed in the "File information" section. The package file name format is as follows:

Product version-yymmdd-kbnnnnnn-processor type
For example, "Wincepb60-110128-kb2492159-armv4i.msi" is the Windows Embedded CE 6.0 Platform Builder fix that was released in January 2011, that is documented in update 2492159, and that applies to ARMV4i processors.

To resolve this problem immediately, download this Windows Embedded CE 6.0 Monthly Update from the following Microsoft website:
Windows Embedded CE 6.0

Prerequisites

This update is supported only if all previously issued updates for this product have also been installed.

Restart requirement

After you apply this update, you must perform a clean build of the whole platform. To do this, use one of the following methods:
  • On the Build menu, click Clean Solution, and then click Build Solution.
  • On the Build menu, click Rebuild Solution.
You do not have to restart the computer after you apply this software update.

Update replacement information

This update does not replace any other updates.

File information

The English version of this hotfix has the file attributes (or later file attributes) that are listed in the following table. The dates and times for these files are listed in Coordinated Universal Time (UTC). When you view the file information, it is converted to local time. To find the difference between UTC and local time, use the Time Zone tab in the Date and Time item in Control Panel.
Collapse this imageExpand this image
assets folding start collapsed
Collapse this tableExpand this table
File nameFile sizeDateTimePath
Dwdmpgen.cpp214,23908-Mar-201302:19Private\Winceos\Coreos\Nk\Osaxs
Osaxst0.lib1,037,95408-Mar-201302:18Public\Common\Oak\Lib\Armv4i\Debug
Osaxst0.lib437,41008-Mar-201302:18Public\Common\Oak\Lib\Armv4i\Retail
Osaxst0.lib997,43008-Mar-201302:18Public\Common\Oak\Lib\Mipsii\Debug
Osaxst0.lib428,79808-Mar-201302:18Public\Common\Oak\Lib\Mipsii\Retail
Osaxst0.lib999,16008-Mar-201302:19Public\Common\Oak\Lib\Mipsii_fp\Debug
Osaxst0.lib431,00208-Mar-201302:18Public\Common\Oak\Lib\Mipsii_fp\Retail
Osaxst0.lib1,005,50808-Mar-201302:19Public\Common\Oak\Lib\Mipsiv\Debug
Osaxst0.lib434,89408-Mar-201302:19Public\Common\Oak\Lib\Mipsiv\Retail
Osaxst0.lib1,007,39408-Mar-201302:19Public\Common\Oak\Lib\Mipsiv_fp\Debug
Osaxst0.lib436,85408-Mar-201302:19Public\Common\Oak\Lib\Mipsiv_fp\Retail
Osaxst0.lib909,05008-Mar-201302:19Public\Common\Oak\Lib\Sh4\Debug
Osaxst0.lib403,45208-Mar-201302:19Public\Common\Oak\Lib\Sh4\Retail
Osaxst0.lib922,13008-Mar-201302:18Public\Common\Oak\Lib\X86\Debug
Osaxst0.lib409,17008-Mar-201302:18Public\Common\Oak\Lib\X86\Retail
Collapse this imageExpand this image
assets folding end collapsed


References

For more information about software update terminology, click the following article number to view the article in the Microsoft Knowledge Base:
824684 Description of the standard terminology that is used to describe Microsoft software updates

Properties

Article ID: 2826750 - Last Review: April 8, 2013 - Revision: 1.0
Applies to
  • Windows Embedded CE 6.0 R3
Keywords: 
kbqfe kbfix kbsurveynew kbexpertiseinter atdownload KB2826750

Give Feedback

 

Contact us for more help

Contact us for more help
Connect with Answer Desk for expert help.
Get more support from smallbusiness.support.microsoft.com