The text of WINS event log messages has been improved in
Windows Server so that the messages are easier to understand. This article
lists the revised event log messages for event ID 4096 to event ID
4209.
For additional
information about WINS event log messages for event ID 4210 to 5300, click the
following article number to view the article in the Microsoft Knowledge Base:
316836
(http://support.microsoft.com/kb/316836/EN-US/
)
Windows Server WINS Event Log Messages, Part 2: Event ID 4210 to Event ID 5300
4096 - WINS_EVT_LOG_INITED WINS has initialized its log
for this invocation.
4097 - WINS_EVT_WINS_OPERATIONAL WINS initialized
properly and is now fully operational.
4098 - WINS_EVT_ORDERLY_SHUTDOWN WINS was terminated
by the service controller. WINS will gracefully terminate.
4099 - WINS_EVT_ADMIN_ORDERLY_SHUTDOWN WINS is being
gracefully terminated by the administrator. The address of the administrator is
%1.
4100 - WINS_EVT_ADMIN_ABRUPT_SHUTDOWN WINS is being
abruptly terminated by the administrator. The address of the administrator is
%1.
4101 - WINS_EVT_INVALID_OPCODE WINS received a Name
Request with an invalid operation code. The request is being thrown
away.
4102 - WINS_EVT_CONN_ABORTED The connection was
aborted by the remote WINS. Remote WINS may not be configured to replicate with
the server.
4103 - WINS_EVT_NO_RECS There are no records in the
registry for the key.
4104 - WINS_EVT_NO_PULL_RECS There are no pull
records.
4105 - WINS_EVT_NO_PUSH_RECS There are no push
records.
4106 - WINS_EVT_NO_RECS_IN_NAM_ADD_TBL The WINS
database of name-to-address mappings is empty. It could mean that a previous
invocation of WINS created the database and then went down before any
registration could be done.
4107 - WINS_EVT_NO_RECS_IN_OWN_ADD_TBL The WINS
database of owner-to-address mappings is empty. It could mean that a previous
invocation of WINS created the table and then went down before its own entry
could be added. The WINS server went down very fast (even before all its
threads could become fully operational).
4108 - WINS_EVT_CANT_GET_INITRPL_VAL WINS could not
read the InitTimeReplication field of the pull/push key.
4109 - WINS_EVT_CANT_GET_REFRESH_INTERVAL_VAL WINS
could not read the Refresh interval from the registry
4110 - WINS_EVT_CANT_GET_TOMBSTONE_INTERVAL_VAL WINS
could not read the Tombstone interval from the registry
4111 - WINS_EVT_CANT_GET_VERIFY_INTERVAL_VAL WINS
could not read the Verify interval from the registry
4112 - WINS_EVT_CANT_GET_RETRY_COUNT WINS could not
read the retry count for retrying communication with a remote WINS.
4113 - WINS_EVT_CANT_GET_TOMBSTONE_TIMEOUT_VAL WINS
could not read the Tombstone Timeout from the registry.
4114 - WINS_EVT_CANT_GET_CC_INTERVAL_VAL WINS could
not read the ConsistencyCheck value (type DWORD) from the
Parameters\ConsistencyCheck subkey in the registry. The first consistency check
is done at the time specified in the SpTime entry under the ConsistencyCheck
subkey and is limited by the MaxRecsAtATime value. If the time is not
specified, the check is done at 2 am.
To correct the problem, open
the registry and verify that the ConsistencyCheck subkey has been correctly
sent up and all required values have been set. Correct the values, as
needed.
4115 - WINS_EVT_CANT_GET_CC_MAX_RECS_AAT_VAL WINS
could not read the MaxRecsAtATime value (type DWORD) in the
Wins\Parameters\ConsistencyCheck subkey of the registry. Set this value if you
do not want WINS to replicate more than a set number of records in one cycle
while doing periodic consistency checks of the WINS database. When doing a
consistency check, WINS replicates all records of an owner WINS by either going
to that WINS or to a replication partner. At the end of doing a consistency
check for an owner's records, it checks to see if it has replicated more than
the specified value in the current consistency check cycle. If the value has
been exceeded, the consistency check stops, otherwise it continues. In the next
cycle, it starts from where it left off and wraps around to the first owner if
required.
4116 - WINS_EVT_CANT_GET_CC_USE_RPL_PNRS_VAL WINS
could not read the UseRplPnrs value of the Wins\Parameters\ConsistencyCheck
key. If this value is set to a non-zero (DWORD) value, WINS will do a
consistency check of the owners in its database by going to one or more of its
replication partners. If the owner of the records happens to be a replication
partner, WINS will go to it, otherwise it will pick one at random. Set this
value if you have a large number of WINSs in your configuration and/or if you
do not want the local WINS to go to any WINS that is not a replication
partner.
4117 - WINS_EVT_CC_STATS WINS just did a consistency
check on the records owned by the WINS with the address, %1. The number of
records inserted, updated, and deleted are in the data section (second, third,
fourth DWORDS).
4118 - WINS_EVT_CC_FAILED WINS could not do a
consistency check on the records. This could be because WINS was directed to do
the consistency check only with replication partners and it currently does not
have any pull replication partners. To get around this problem, you should
either allow WINS to do consistency check with owner WINSs or configure the
WINS with one or more pull partners.
4119 - WINS_EVT_PKT_FORMAT_ERR WINS received a packet
that has the wrong format. For example, a label may be More than 63
octets.
4120 - WINS_EVT_NO_RECS_RETRIEVED No records meeting
the %1 criteria were found in the WINS database.
4121 - WINS_EVT_NO_RPL_RECS_RETRIEVED WINS's
Replicator could not find any records in the WINS database. This means there
are no active or tombstone records in the database. It could be that the
records being requested by a remote WINS server have either been released or do
not exist.
4122 - WINS_EVT_GRP_LIMIT_REACHED The special group
has reached its limit. WINS cannot add any more members.
4123 - WINS_EVT_OWNER_LIMIT_REACHED The address
database already has reached the limit of owners. This is 100. This error was
noticed while attempting to add the address given in the data
section.
4124 - WINS_EVT_UPD_NTF_NOT_ACCEPTED The WINS server
received an update notification from the non-configured WINS server at the
address, %1. The WINS server rejected it. This means the remote WINS server is
not in the list of Push partners (WINS servers under the Pull key) and the
administrator has prohibited (using the registry) replication with
non-configured WINS servers. If you want this WINS server to accept update
notifications from non-configured WINS servers then set the
Wins\Paramaters\RplOnlyWCnfPnrs value in the registry to 0.
4125 - WINS_EVT_UPD_NTF_ACCEPTED WINS received an
update notification from the WINS with the address, %1. WINS accepted
it.
4126 - WINS_EVT_ADD_VERS_MAP_REQ_NOT_ACCEPTED The WINS
server received a pull request from the non-configured WINS server with the
address, %1. The WINS server rejected it since the remote WINS server is not in
the list of Pull partners (WINS servers under the Pull key) and the
administrator has prohibited (using the registry) replication with
non-configured partners. If you want this WINS server to accept update
notifications from WINS servers not in the "pull partner" list, then set the
"replication only with configured partners" value in the registry to
0.
4127 - WINS_EVT_CANT_OPEN_DATAFILES_KEY The datafiles
key could not be opened.
4128 - WINS_EVT_OPEN_NETBT_KEY_ERR The NetBios over
TCP/IP (NetBT) key could not be opened.
4129 - WINS_EVT_QUERY_NETBT_KEY_ERR The NetBios over
TCP/IP (NetBT) key could not be queried.
4130 - WINS_EVT_WRK_THD_CREATED A worker thread was
created by the administrator.
4131 - WINS_EVT_WRK_THD_TERMINATED A worker thread was
terminated by the administrator.
4132 - WINS_EVT_WINS_ENTRY_DELETED The owner-address
mapping table had an entry with a non-zero owner ID and an address the same as
the local WINS address. The entry has been marked as deleted in the in-memory
table.
4133 - WINS_EVT_INF_REM_WINS_EXC An error occurred
while trying to inform a remote WINS to update the version number.
4134 - WINS_EVT_INF_REM_WINS The local WINS is going
to inform a remote WINS to update the version number of a record. This is
because the local WINS encountered a conflict between an active owned name and
an active replica that it pulled from a replication partner.
4135 - WINS_EVT_REM_WINS_INF The local WINS has been
informed by a remote WINS with address, %1, to update the version number of a
record. This is because the remote WINS encountered a conflict between an
active owned name and an active replica that it pulled from a replication
partner.
4136 - WINS_EVT_CANT_FIND_REC A remote WINS requested
the update of the version stamp of a record, but the record could not be found.
Check to see if the record was deleted or updated.
4137 - WINS_EVT_NAME_MISMATCH A name mismatch was
noticed while verifying the validity of old replicas. The local record has the
name %1 while the replica pulled in from the WINS that owns this record has the
name %2. This could mean that the remote WINS was brought down and then up
again but its version counter value was not set to its previous value before
termination.
4138 - WINS_EVT_VERS_COUNTER_CHANGED The value of the
version ID counter was changed. The new value (Low 32 bits) is given in the
data section.
4139 - WINS_EVT_CNF_CHANGE The WINS replication
request is being ignored since WINS suspects that the Wins\Partners key
information has changed (because it received a notification From the registry)
which makes the current request pertaining to the partner out of
date.
4140 - WINS_EVT_DUP_ENTRY_DEL WINS is deleting all
records of the WINS with owner ID, %d. This owner ID corresponds to the
address, %s.
4141 - WINS_EVT_REC_PULLED WINS pulled records from a
WINS while doing %1. The partner's address and the owner's address whose
records were pulled are given in the data section (second and third DWORD
respectively). The number of records pulled is the fourth DWORD.
4142 - WINS_EVT_CC_NO_RECS WINS performed a
consistency check on the records. The number of records pulled, The address of
the WINS whose records were pulled, and the address of the WINS from which
these records were pulled are given in the second, third, and fourth DWORDs in
the data section.
4143 - WINS_EVT_SCV_RECS WINS scavenged its records in
the WINS database. The number of records scavenged is given in the data
section.
4144 - WINS_EVT_SCV_RPLTOMB WINS scavenged replica
tombstones in the WINS database. The number of records Scavenged is given in
the data section.
4145 - WINS_EVT_SCV_CLUTTER WINS revalidated old
active replicas in the WINS database.
4146 - WINS_EVT_LOG_CLOSE WINS Performance Monitor
Counters is closing the event log.
4147 - WINS_EVT_DEL_RECS WINS has deleted records of a
partner. The internal ID of the partner whose records were deleted, the minimum
version number (low word, high word), and the maximum version number (low word,
high word) of the records deleted are given in the data section.
NOTE: The error codes 8000 to 4020 are reserved for Warning events
4148 - WINS_EVT_VERS_MISMATCH The local WINS server
received a request from a remote WINS server that is not the same version.
Because the WINS servers are not compatible, the connection was terminated. The
version number of the remote WINS server is given in the data
section.
4149 - WINS_EVT_WINSOCK_SEND_MSG_ERR Winsock Send
could not send all the bytes. The connection could have been aborted by the
remote client.
4150 - WINS_EVT_ADJ_TIME_INTVL_R WINS adjusted the
scavenging related time interval, %1, so that it is compatible with the
replication time intervals. The adjusted value for this scavenging parameter is
given in the data section (second DWORD). This value was computed by WINS using
an algorithm that may use the maximum replication time interval specified. The
current value achieves a good balance between consistency of databases across
the network of WINS servers and the performance of the WINS servers.
4151 - WINS_EVT_ADJ_TIME_INTVL WINS adjusted the
scavenging related time interval, %1. The adjusted value for this scavenging
parameter is given in the data section (second DWORD). This value was computed
by WINS using an algorithm that tries to achieve a good balance between
consistency of databases across the network of WINS servers and the performance
of the WINS servers.
4152 - WINS_EVT_WINSOCK_SELECT_TIMED_OUT The timeout
period has expired on a call to another WINS server. Assuming that the network
and routers are working properly, either the remote WINS server is overloaded,
or its TCP listener thread has terminated.
4153 - WINS_EVT_UNABLE_TO_VERIFY The Scavenger thread
found active replicas that needed to be verified with the owner WINS server
since they were older than the verify time interval. The table of
owner-to-address mappings indicated the WINS was not active.
4154 - WINS_EVT_LIMIT_MULTIH_ADD_REACHED The name
registration packet that was just received has too many addresses. The maximum
number of addresses for a multi-homed client is 25. The number of addresses
found in the packet is given in the data section.
4155 - WINS_EVT_REPLICA_CLASH_W_STATIC A replica
clashed with the static record, %1, in the WINS database. The replica was
rejected.
4156 - WINS_EVT_RPC_NOT_INIT WINS could not initialize
the administrator interface because of a problem with the Remote Procedure Call
(RPC) service. You may not be able to administer WINS. Make sure that the RPC
service is running.
4157 - WINS_EVT_NO_NTF_PERS_COMM_FAIL WINS did not
send a notification message to the WINS server whose address is given in the
data section. There were a number of communications failures with that server
in the past few minutes.
4158 - WINS_EVT_REL_DIFF_OWN WINS received a release
for the non-owned name, %1. This name is owned by the WINS whose owner ID is
given in the data section. Run winscl.exe to get the owner ID to address
mapping.
4159 - WINS_EVT_REC_DELETED The administrator deleted
a record with the name, %1.
4160 - WINS_EVT_DB_RESTORED WINS could not start
because of a database error. WINS restored the old database from the backup
directory and will come up using this database.
4161 - WINS_EVT_PARTIAL_RPL_TYPE A non-zero
replication type applies for this partner. This means only a subset of records
will be replicated between the local WINS and this partner. If later you want
to get records that did not replicate, you can either pull them using
winscl.exe in the Windows 2000 Resource Kit, or delete all owners acquired only
through this partner and initiate replication after that to reacquire all their
records. The partner's address is given in the second DWORD of the data
section.
4162 - WINS_EVT_PNR_PARTIAL_RPL_TYPE A partner has
requested only a subset of records. This means we won't replicate all the
records in the range requested. Check the partner's registry to see what
replication type applies to it. The partner's address is given in the second
DWORD of the data section. 4163 - WINS_EVT_ADJ_MAX_RECS_AAT
WINS adjusted the Maximum Records at a time parameter of
the ConsistencyCheck key. The value specified, %2, was changed to the minimum
value, %1. These are the maximum number of records that will be replicated at
any one time for a consistency check.
4164 - WINS_EVT_FORCE_SCV_R_T WINS was forced to
scavenge replica tombstones of a WINS. The person with administrative rights on
the computer forced the scavenging using winscl.exe. WINS does not
scavenge replica tombstones unless they have timed out and the WINS has been
running for at least 3 days (This is to ensure that the tombstones have
replicated to other WINSs). In this case, the tombstones were timed out but the
WINS had not been up for 3 days. The replica tombstones were deleted. This
deletion does not constitute a problem unless you have WINS servers that are
primary and backup to clients but not both Push and Pull partners of each
other. If you do have such WINSs, there is a low probability that this action
will result in database inconsistency but if it does (as you will discover
eventually), you can get back to a consistent state by initiating consistency
checks using winscl.exe. NOTE: The consistency check is a network and resource intensive
operation, you should initiate it only with a full understanding of what it
does. You are better off creating the ConsistencyCheck subkey under
Wins\Parameters.
4165 - WINS_EVT_ABNORMAL_SHUTDOWN WINS has encountered
an error that caused it to shut down.The exception code is the second DWORD of
the data section. Check previous event log entries to determine a more specific
cause for the error.
4166 - WINS_EVT_RPLPULL_ABNORMAL_SHUTDOWN The
replication Pull thread is shutting down due to an error. Restart
WINS.
4167 - WINS_EVT_RPLPUSH_ABNORMAL_SHUTDOWN The
replication Push thread is shutting down due to an error. Restart
WINS.
4168 - WINS_EVT_CHL_ABNORMAL_SHUTDOWN The Name
Challenge thread is shutting down due to an error. Restart WINS.
4169 - WINS_EVT_WRK_ABNORMAL_SHUTDOWN A Worker thread
is shutting down due to an error. Restart WINS.
4170 - WINS_EVT_CANT_INIT An abnormal error occurred
during the WINS initialization. Check the application and system logs for
information on the cause. WINS may need to be restarted.
4171 - WINS_EVT_CANT_INIT_W_DB WINS could not properly
set up the WINS database. Look at the application log for errors from the
Exchange component, ESENT.
4172 - WINS_EVT_CANT_CREATE_WRK_THD A worker thread
could not be created. The computer may be low on resources.
4173 - WINS_EVT_CANT_CREATE_THD A thread could not be
created. The computer may be low on resources.
4174 - WINS_EVT_CANT_CREATE_EVT An event could not be
created.
4175 - WINS_EVT_CANT_CREATE_CHL_THD The Name Challenge
Request thread could not be created.
4176 - WINS_EVT_CANT_OPEN_KEY A registry key could not
be created or opened.
4177 - WINS_EVT_CANT_OPEN_WINS_KEY The WINS
configuration key could not be created or opened. Check to see if the
permissions on the key are set properly, system resources are low, or the
registry is having a problem.
4178 - WINS_EVT_CANT_OPEN_PULL_KEY The WINS Pull
configuration key could not be created or opened. Check to see if the
permissions on the key are set properly, system resources are low, or the
registry is having a problem.
4179 - WINS_EVT_CANT_OPEN_PUSH_KEY The WINS Push
configuration key could not be created or opened. Check to see if the
permissions on the key are set properly, system resources are low, or the
registry is having a problem.
4180 - WINS_EVT_CANT_OPEN_PARAMETERS_KEY The
WINS\Parameters key could not be created or opened. Check to see if the
permissions on the key are set properly, system resources are low, or the
registry is having a problem.
4181 - WINS_EVT_CANT_OPEN_CC_KEY The
WINS\Parameters\ConsistencyCheck subkey could not be created or opened. This
key should be there if you want WINS to do consistency checks on its database
periodically. NOTE: Consistency checks have the potential of consuming
large amounts of network bandwidth. Check to see if the permissions on the
key are set properly, system resources are low, or the registry is having a
problem.
4182 - WINS_EVT_CANT_CREATE_REG_EVT The registry
change notification event could not be created. Check to see if system
resources are low.
4183 - WINS_EVT_WRONG_TIME_FORMAT The correct time
format is hh:mm:ss. Check the value of SpTime in the registry.
4184 - WINS_EVT_REG_NTFY_FN_ERR The registry
notification function returned an error.
4185 - WINS_EVT_NBTSND_REG_RSP_ERR The Name
Registration Response could not be sent due to an error. This error was
encountered by a NetBT request thread
4186 - WINS_EVT_RPLSND_REG_RSP_ERR The Name
Registration Response could not be sent due to an error. This error was
encountered by a RPL thread.
4187 - WINS_EVT_CHLSND_REG_RSP_ERR The Name
Registration Response could not be sent due to an error. This error was
encountered by the Name Challenge Thread.
4188 - WINS_EVT_SND_REL_RSP_ERR The Name Release
Response could not be sent due to an error. This error is often caused by a
problem with the NetBIOS over TCP/IP (NetBT) interface.
4189 - WINS_EVT_SND_QUERY_RSP_ERR The Name Query
Response could not be sent due to an error. This error is often caused by a
problem with the NetBIOS over TCP/IP (NetBT) interface.
4190 - WINS_EVT_F_CANT_FIND_REC A record could not be
registered because it already existed. However, the same record then could not
be found. The WINS database might be corrupt. Check the application log for the
Exchange component, ESENT.
4191 - WINS_EVT_CANT_CREATE_HEAP WINS could not create
a heap because of a resource shortage. Check to see if the computer is running
short of virtual memory.
4192 - WINS_EVT_SFT_ERR An error occurred from which
WINS will try to recover. If the recovery fails, check previous event log
entries to determine what prevented a successful recovery. Take the appropriate
action to solve the error that prevented recovery.
4193 - WINS_EVT_CANT_CREATE_UDP_SOCK WINS could not
create the notification socket. Make sure the TCP/IP driver is installed and
running properly.
4194 - WINS_EVT_CANT_CREATE_NTF_SOCK WINS could not
create the User Datagram Protocol (UDP) socket to listen for Connection
notification messages sent by another Pull thread in the local WINS.
4195 -
WINS_EVT_CANT_CREATE_TCP_SOCK_FOR_LISTENING WINS could not create the TCP
socket for listening to TCP connections. Make sure the TCP/IP driver is
installed and running properly.
4196 - WINS_EVT_CANT_CREATE_TCP_SOCK_FOR_CONN WINS
could not create the TCP socket for making a TCP connection. Make sure the
TCP/IP stack is installed and running properly.
4197 - WINS_EVT_WINSOCK_BIND_ERR An address could not
bind to a socket. Make sure the TCP/IP stack is installed And running
properly. This event might mean that the 'nameserver' port (specified in
the services file) which is used as the default by WINS for replication and
discovering other WINSs has been taken by another process or service running on
this computer. You have two options - either bring down that other process or
service or direct WINS to use another port. If you choose the second option,
set the value 'PortNo' (REG_DWORD) under the Wins\Parameters subkey in the
registry to 1512. NOTE: Changing the port number this way will prevent
this WINS from replicating or discovering other WINSs unless they too are
directed to use the same port number as this WINS.
4198 - WINS_EVT_WINSOCK_LISTEN_ERR WINS could not
listen on the Winsock socket.
4199 - WINS_EVT_WINSOCK_SELECT_ERR Winsock Select
returned with an error.
4200 - WINS_EVT_WINSOCK_ERR %1 returned with an error
code of %2.
4201 - WINS_EVT_WINSOCK_GETSOCKNAME_ERR WINS created a
socket and called the 'bind' WinSock API to bind a handle to it. On calling
'getsockname' to determine the address bound, WINS received an
error.
4202 - WINS_EVT_WINSOCK_CONNECT_ERR An attempt to
connect to the remote WINS server with address %1 returned with an error. Check
to see that the remote WINS server is running and available, and that WINS is
running on that server.
4203 - WINS_EVT_WINSOCK_ACCEPT_ERR WINS could not
accept on a socket.
4204 - WINS_EVT_WINSOCK_RECVFROM_ERR WINS could not
read from the User Datagram Protocol (UDP) socket.
4205 - WINS_EVT_NETBT_RECV_ERR WINS could not read
from NetBIOS over TCP/IP (NetBT).
4206 - WINS_EVT_WINSOCK_CLOSESOCKET_ERR WINS could not
close a socket.
4207 - WINS_EVT_WINSOCK_SENDTO_MSG_ERR A Winsock
Sendto message could not send all the bytes.
4208 - WINS_EVT_NETBT_SEND_ERR WINS could not send a
User Datagram Protocol (UDP) message to a WINS client.
4209 - WINS_EVT_WINSOCK_SENDTO_ERR A Winsock Sendto
message returned with an error.