SYMPTOMS

When you view the properties of any COM+ application from the Component Services Microsoft Management Console (MMC) on the inactive node of a BizTalk cluster, the XLANG schedules may fail after failover. This is specific only to any COM+ application that has an activation type of server application.

CAUSE

When you view COM+ application properties on any COM+ server application, a copy of the XLANG scheduler engine starts. When this occurs, BizTalk Server failover does not behave as expected because an instance of the XLANG scheduler is running.

RESOLUTION

Make sure to shut down the copy of the XLANG Scheduler engine that is started by the component service when you finish viewing the COM+ application properties on the inactive node. When you view the properties in this scenario, follow these steps:
  1. View the properties on the COM+ server application.
  2. Click to select the XLANG scheduler COM+ application in the Component Service MMC.
  3. Right-click the XLANG scheduler COM+ application, and then click Shut Down.
  4. Close the Component Services MMC.

Properties

Article ID: 323572 - Last Review: May 23, 2003 - Revision: 2.1
APPLIES TO
  • Microsoft BizTalk Server 2000 Standard Edition
  • Microsoft BizTalk Server 2000 Service Pack 1a
  • Microsoft BizTalk Server 2000 Service Pack 2
  • Microsoft BizTalk Server 2002 Standard Edition
Keywords: 
kbfix kbprb KB323572

Give Feedback

 

Contact us for more help

Contact us for more help
Connect with Answer Desk for expert help.
Get more support from smallbusiness.support.microsoft.com