For a Microsoft Visual Studio 2005 version of this
article, see
904795 (http://support.microsoft.com/kb/904795/).
On This Page
SUMMARY
This step-by-step article describes how to access serial
ports and how to access parallel ports by using Microsoft Visual Basic .NET.
This article also contains sample code that illustrates the concepts that are
discussed in this article.
Use the MSComm control in
Visual Basic .NET to access serial ports
Because no Microsoft .NET Framework classes exist to access the
communications resources that connected to your computer, you can use the MSComm control in Microsoft Visual Basic 6.0. The MSComm control provides serial communications for your application by
enabling the transmission and reception of data through a serial port. To
implement basic serial communications by using a modem, follow these steps:
1.
Start Microsoft Visual Studio .NET.
2.
On the File menu, point to
New, and then click Project.
3.
Under Project Types, click Visual
Basic Projects.
4.
Under Templates, click Console
Application.
5.
In the Name box, type
MyConsoleApplication, and then click
OK.
By default, Module1.vb is created.
6.
Right-click the MyConsoleApplication
project, and then click Add Reference.
7.
Click the COM tab, click Microsoft
Comm Control 6.0 under Component Name, click
Select, and then click OK.
Note To use the MSComm control, you must install the related COM components of Microsoft
Visual Basic 6.0 on the same computer that has Microsoft Visual Studio .NET
installed.
For more information about license issues when you use Visual
Basic 6.0 controls in Visual Studio .NET, click the following article number to
view the article in the Microsoft Knowledge Base:
318597 (http://support.microsoft.com/kb/318597/)
Errors when you use Visual Basic 6.0 controls in Visual Studio .NET
8.
Replace the code in Module1.vb with the following code
example.
Imports MSCommLib
Module Module1
Sub Main()
'New a MSComm control
Dim MSComm1 As MSComm
MSComm1 = New MSComm
' Buffer to hold input string.
Dim Buffer As String
' Use the COM1 serial port.
MSComm1.CommPort = 1
' 9600 baud, no parity, 8 data, and 1 stop bit.
MSComm1.Settings = "9600,N,8,1"
' Tell the control to read the whole buffer when Input is used.
MSComm1.InputLen = 0
' Open the serial port.
MSComm1.PortOpen = True
Console.WriteLine("Open the serial port.")
' Tell the control to make the Input property return text data.
MSComm1.InputMode() = InputModeConstants.comInputModeText
'Clear the receive buffer.
MSComm1.InBufferCount() = 0
' Send the attention command to the modem.
MSComm1.Output = "ATV1Q0" & Chr(13)
Console.WriteLine("Send the attention command to the modem.")
Console.WriteLine("Wait for the data to come back to the serial port...")
' Make sure that the modem responds with "OK".
' Wait for the data to come back to the serial port.
Do
Buffer = Buffer & MSComm1.Input
Loop Until InStr(Buffer, "OK" & vbCrLf)
' Read the "OK" response data in the serial port.
' Close the serial port.
Console.WriteLine("Read the OK response data in the serial port.")
MSComm1.PortOpen = False
Console.WriteLine("Close the serial port.")
End Sub
End Module
9.
Press CRTL+F5 to build and run this project. You will
receive the following output messages:
Open the serial
port. Send the attention command to the modem. Wait for data to come
back to the serial port... Read the OK response data in the serial
port. Close the serial port.
Use platform invoke services to call Win32 API functions in Visual Basic .NET to access serial and parallel ports
To do this, follow these steps:
1.
Start Microsoft Visual Studio .NET.
2.
On the File menu, point to
New, and then click Project.
3.
Under Project Types, click Visual
Basic Projects.
4.
Under Templates, click Console
Application.
5.
In the Name text box, type
MyConsoleApplication, and then click
OK.
By default, Module1.vb is created.
6.
Add the following code to Module1.vb before the
Module Module1 statement:
Option Strict On
' Define a CommException class that inherits from the ApplicationException class,
' and then throw an object of type CommException when you receive an error message.
Class CommException
Inherits ApplicationException
Sub New(ByVal Reason As String)
MyBase.New(Reason)
End Sub
End Class
7.
Declare structures, constants, and references to external
functions that are in Kernel32.dll
To call unmanaged functions from
your managed Visual Basic .NET application, you must declare references to the
structures that you pass as parameters to the unmanaged functions, and you must
declare the constants that you pass as parameters to the unmanaged functions.
To do this, add the following code to Module1.vb after the Module Module1 statement:
'Declare structures.
Public Structure DCB
Public DCBlength As Int32
Public BaudRate As Int32
Public fBitFields As Int32 'See Comments in Win32API.Txt
Public wReserved As Int16
Public XonLim As Int16
Public XoffLim As Int16
Public ByteSize As Byte
Public Parity As Byte
Public StopBits As Byte
Public XonChar As Byte
Public XoffChar As Byte
Public ErrorChar As Byte
Public EofChar As Byte
Public EvtChar As Byte
Public wReserved1 As Int16 'Reserved; Do Not Use
End Structure
Public Structure COMMTIMEOUTS
Public ReadIntervalTimeout As Int32
Public ReadTotalTimeoutMultiplier As Int32
Public ReadTotalTimeoutConstant As Int32
Public WriteTotalTimeoutMultiplier As Int32
Public WriteTotalTimeoutConstant As Int32
End Structure
'Declare constants.
Public Const GENERIC_READ As Int32 = &H80000000
Public Const GENERIC_WRITE As Int32 = &H40000000
Public Const OPEN_EXISTING As Int32 = 3
Public Const FILE_ATTRIBUTE_NORMAL As Int32 = &H80
Public Const NOPARITY As Int32 = 0
Public Const ONESTOPBIT As Int32 = 0
'Declare references to external functions.
Public Declare Auto Function CreateFile Lib "kernel32.dll" _
(ByVal lpFileName As String, ByVal dwDesiredAccess As Int32, _
ByVal dwShareMode As Int32, ByVal lpSecurityAttributes As IntPtr, _
ByVal dwCreationDisposition As Int32, ByVal dwFlagsAndAttributes As Int32, _
ByVal hTemplateFile As IntPtr) As IntPtr
Public Declare Auto Function GetCommState Lib "kernel32.dll" (ByVal nCid As IntPtr, _
ByRef lpDCB As DCB) As Boolean
Public Declare Auto Function SetCommState Lib "kernel32.dll" (ByVal nCid As IntPtr, _
ByRef lpDCB As DCB) As Boolean
Public Declare Auto Function GetCommTimeouts Lib "kernel32.dll" (ByVal hFile As IntPtr, _
ByRef lpCommTimeouts As COMMTIMEOUTS) As Boolean
Public Declare Auto Function SetCommTimeouts Lib "kernel32.dll" (ByVal hFile As IntPtr, _
ByRef lpCommTimeouts As COMMTIMEOUTS) As Boolean
Public Declare Auto Function WriteFile Lib "kernel32.dll" (ByVal hFile As IntPtr, _
ByVal lpBuffer As Byte(), ByVal nNumberOfBytesToWrite As Int32, _
ByRef lpNumberOfBytesWritten As Int32, ByVal lpOverlapped As IntPtr) As Boolean
Public Declare Auto Function ReadFile Lib "kernel32.dll" (ByVal hFile As IntPtr, _
ByVal lpBuffer As Byte(), ByVal nNumberOfBytesToRead As Int32, _
ByRef lpNumberOfBytesRead As Int32, ByVal lpOverlapped As IntPtr) As Boolean
Public Declare Auto Function CloseHandle Lib "kernel32.dll" (ByVal hObject As IntPtr) As Boolean
8.
Before you can access a serial port or a parallel port, you
must obtain a handle to the appropriate port and then configure the port
communications. To do this, add the following initialization code to Module1.vb
after the Sub Main statement.
Note To establish communication with the LPTx port, you must stop the Print Spooler service. To do this, use
the Services tool in Administrative Tools.
' Declare the local variables that you will use in the code.
Dim hSerialPort, hParallelPort As IntPtr
Dim Success As Boolean
Dim MyDCB As DCB
Dim MyCommTimeouts As COMMTIMEOUTS
Dim BytesWritten, BytesRead As Int32
Dim Buffer() As Byte
' Declare the variables to use for encoding.
Dim oEncoder As New System.Text.ASCIIEncoding
Dim oEnc As System.Text.Encoding = oEncoder.GetEncoding(1252)
' Convert String to Byte().
Buffer = oEnc.GetBytes("Test")
Try
' Access the serial port.
Console.WriteLine("Accessing the COM1 serial port")
' Obtain a handle to the COM1 serial port.
hSerialPort = CreateFile("COM1", GENERIC_READ Or GENERIC_WRITE, 0, IntPtr.Zero, _
OPEN_EXISTING, FILE_ATTRIBUTE_NORMAL, IntPtr.Zero)
' Verify that the obtained handle is valid.
If hSerialPort.ToInt32 = -1 Then
Throw New CommException("Unable to obtain a handle to the COM1 port")
End If
' Retrieve the current control settings.
Success = GetCommState(hSerialPort, MyDCB)
If Success = False Then
Throw New CommException("Unable to retrieve the current control settings")
End If
' Modify the properties of the retrieved DCB structure as appropriate.
' WARNING: Make sure to modify the properties according to their supported values.
MyDCB.BaudRate = 9600
MyDCB.ByteSize = 8
MyDCB.Parity = NOPARITY
MyDCB.StopBits = ONESTOPBIT
' Reconfigure COM1 based on the properties of the modified DCB structure.
Success = SetCommState(hSerialPort, MyDCB)
If Success = False Then
Throw New CommException("Unable to reconfigure COM1")
End If
' Retrieve the current time-out settings.
Success = GetCommTimeouts(hSerialPort, MyCommTimeouts)
If Success = False Then
Throw New CommException("Unable to retrieve current time-out settings")
End If
' Modify the properties of the retrieved COMMTIMEOUTS structure as appropriate.
' WARNING: Make sure to modify the properties according to their supported values.
MyCommTimeouts.ReadIntervalTimeout = 0
MyCommTimeouts.ReadTotalTimeoutConstant = 0
MyCommTimeouts.ReadTotalTimeoutMultiplier = 0
MyCommTimeouts.WriteTotalTimeoutConstant = 0
MyCommTimeouts.WriteTotalTimeoutMultiplier = 0
' Reconfigure the time-out settings, based on the properties of the modified COMMTIMEOUTS structure.
Success = SetCommTimeouts(hSerialPort, MyCommTimeouts)
If Success = False Then
Throw New CommException("Unable to reconfigure the time-out settings")
End If
' Write data to COM1.
Console.WriteLine("Writing the following data to COM1: Test")
Success = WriteFile(hSerialPort, Buffer, Buffer.Length, BytesWritten, IntPtr.Zero)
If Success = False Then
Throw New CommException("Unable to write to COM1")
End If
' Read data from COM1.
Success = ReadFile(hSerialPort, Buffer, BytesWritten, BytesRead, IntPtr.Zero)
If Success = False Then
Throw New CommException("Unable to read from COM1")
End If
Catch ex As Exception
Console.WriteLine(Ex.Message)
Finally
' Release the handle to COM1.
Success = CloseHandle(hSerialPort)
If Success = False Then
Console.WriteLine("Unable to release handle to COM1")
End If
End Try
Try
' Parallel port.
Console.WriteLine("Accessing the LPT1 parallel port")
' Obtain a handle to the LPT1 parallel port.
hParallelPort = CreateFile("LPT1", GENERIC_READ Or GENERIC_WRITE, 0, IntPtr.Zero, _
OPEN_EXISTING, FILE_ATTRIBUTE_NORMAL, IntPtr.Zero)
' Verify that the obtained handle is valid.
If hParallelPort.ToInt32 = -1 Then
Throw New CommException("Unable to obtain a handle to the LPT1 port")
End If
' Retrieve the current control settings.
Success = GetCommState(hParallelPort, MyDCB)
If Success = False Then
Throw New CommException("Unable to retrieve the current control settings")
End If
' Modify the properties of the retrieved DCB structure as appropriate.
' WARNING: Make sure to modify the properties according to their supported values.
MyDCB.BaudRate = 9600
MyDCB.ByteSize = 8
MyDCB.Parity = NOPARITY
MyDCB.StopBits = ONESTOPBIT
' Reconfigure LPT1 based on the properties of the modified DCB structure.
Success = SetCommState(hParallelPort, MyDCB)
If Success = False Then
Throw New CommException("Unable to reconfigure LPT1")
End If
' Retrieve the current time-out settings.
Success = GetCommTimeouts(hParallelPort, MyCommTimeouts)
If Success = False Then
Throw New CommException("Unable to retrieve current time-out settings")
End If
' Modify the properties of the retrieved COMMTIMEOUTS structure as appropriate.
' WARNING: Make sure to modify the properties according to their supported values.
MyCommTimeouts.ReadIntervalTimeout = 0
MyCommTimeouts.ReadTotalTimeoutConstant = 0
MyCommTimeouts.ReadTotalTimeoutMultiplier = 0
MyCommTimeouts.WriteTotalTimeoutConstant = 0
MyCommTimeouts.WriteTotalTimeoutMultiplier = 0
' Reconfigure the time-out settings, based on the properties of the modified COMMTIMEOUTS structure.
Success = SetCommTimeouts(hParallelPort, MyCommTimeouts)
If Success = False Then
Throw New CommException("Unable to reconfigure the time-out settings")
End If
' Write data to LPT1.
' Note: You cannot read data from a parallel port by calling the ReadFile function.
Console.WriteLine("Writing the following data to LPT1: Test")
Success = WriteFile(hParallelPort, Buffer, Buffer.Length, BytesWritten, IntPtr.Zero)
If Success = False Then
Throw New CommException("Unable to write to LPT1")
End If
Catch ex As Exception
Console.WriteLine(Ex.Message)
Finally
' Release the handle to LPT1.
Success = CloseHandle(hParallelPort)
If Success = False Then
Console.WriteLine("Unable to release handle to LPT1")
End If
End Try
Console.WriteLine("Press ENTER to quit")
Console.ReadLine()
9.
On the Build menu, click Build
Solution.
10.
On the Debug menu, click
Start to run the application.
You may receive the
following text in the console:
Accessing the COM1
serial port Writing the following data to COM1: Test
Read the
following data from COM1: Serial Data Accessing
the LPT1 parallel port
Writing the following data to LPT1: Test
Press ENTER to quit
Note Serial Data represents the data that
you read from the serial port.
11.
To close the application, press the ENTER key in the
console.
Before you use the following code example, replace
COM1 with the name of your serial port, and replace
LPT1 with the name of your parallel port.
Note The following code works only when serial devices and parallel
devices are connected to the corresponding ports on the computer. If you do not
connect these devices and you run the program, the program waits indefinitely.
Option Strict On
' Define a CommException class that inherits from the ApplicationException class.
' Then throw an object of type CommException when you receive an error message.
Class CommException
Inherits ApplicationException
Sub New(ByVal Reason As String)
MyBase.New(Reason)
End Sub
End Class
Module Module1
'Declare structures
Public Structure DCB
Public DCBlength As Int32
Public BaudRate As Int32
Public fBitFields As Int32
Public wReserved As Int16
Public XonLim As Int16
Public XoffLim As Int16
Public ByteSize As Byte
Public Parity As Byte
Public StopBits As Byte
Public XonChar As Byte
Public XoffChar As Byte
Public ErrorChar As Byte
Public EofChar As Byte
Public EvtChar As Byte
Public wReserved1 As Int16 'Reserved; Do Not Use
End Structure
Public Structure COMMTIMEOUTS
Public ReadIntervalTimeout As Int32
Public ReadTotalTimeoutMultiplier As Int32
Public ReadTotalTimeoutConstant As Int32
Public WriteTotalTimeoutMultiplier As Int32
Public WriteTotalTimeoutConstant As Int32
End Structure
'Declare constants.
Public Const GENERIC_READ As Int32 = &H80000000
Public Const GENERIC_WRITE As Int32 = &H40000000
Public Const OPEN_EXISTING As Int32 = 3
Public Const FILE_ATTRIBUTE_NORMAL As Int32 = &H80
Public Const NOPARITY As Int32 = 0
Public Const ONESTOPBIT As Int32 = 0
'Declare references to external functions.
Public Declare Auto Function CreateFile Lib "kernel32.dll" _
(ByVal lpFileName As String, ByVal dwDesiredAccess As Int32, _
ByVal dwShareMode As Int32, ByVal lpSecurityAttributes As IntPtr, _
ByVal dwCreationDisposition As Int32, ByVal dwFlagsAndAttributes As Int32, _
ByVal hTemplateFile As IntPtr) As IntPtr
Public Declare Auto Function GetCommState Lib "kernel32.dll" (ByVal nCid As IntPtr, _
ByRef lpDCB As DCB) As Boolean
Public Declare Auto Function SetCommState Lib "kernel32.dll" (ByVal nCid As IntPtr, _
ByRef lpDCB As DCB) As Boolean
Public Declare Auto Function GetCommTimeouts Lib "kernel32.dll" (ByVal hFile As IntPtr, _
ByRef lpCommTimeouts As COMMTIMEOUTS) As Boolean
Public Declare Auto Function SetCommTimeouts Lib "kernel32.dll" (ByVal hFile As IntPtr, _
ByRef lpCommTimeouts As COMMTIMEOUTS) As Boolean
Public Declare Auto Function WriteFile Lib "kernel32.dll" (ByVal hFile As IntPtr, _
ByVal lpBuffer As Byte(), ByVal nNumberOfBytesToWrite As Int32, _
ByRef lpNumberOfBytesWritten As Int32, ByVal lpOverlapped As IntPtr) As Boolean
Public Declare Auto Function ReadFile Lib "kernel32.dll" (ByVal hFile As IntPtr, _
ByVal lpBuffer As Byte(), ByVal nNumberOfBytesToRead As Int32, _
ByRef lpNumberOfBytesRead As Int32, ByVal lpOverlapped As IntPtr) As Boolean
Public Declare Auto Function CloseHandle Lib "kernel32.dll" (ByVal hObject As IntPtr) As Boolean
Sub Main()
' Declare local variables that you will use in the code.
Dim hSerialPort, hParallelPort As IntPtr
Dim Success As Boolean
Dim MyDCB As DCB
Dim MyCommTimeouts As COMMTIMEOUTS
Dim BytesWritten, BytesRead As Int32
Dim Buffer() As Byte
' Declare variables to use for encoding.
Dim oEncoder As New System.Text.ASCIIEncoding
Dim oEnc As System.Text.Encoding = oEncoder.GetEncoding(1252)
' Convert String to Byte().
Buffer = oEnc.GetBytes("Test")
Try
' Serial port.
Console.WriteLine("Accessing the COM1 serial port")
' Obtain a handle to the COM1 serial port.
hSerialPort = CreateFile("COM1", GENERIC_READ Or GENERIC_WRITE, 0, IntPtr.Zero, _
OPEN_EXISTING, FILE_ATTRIBUTE_NORMAL, IntPtr.Zero)
' Verify that the obtained handle is valid.
If hSerialPort.ToInt32 = -1 Then
Throw New CommException("Unable to obtain a handle to the COM1 port")
End If
' Retrieve the current control settings.
Success = GetCommState(hSerialPort, MyDCB)
If Success = False Then
Throw New CommException("Unable to retrieve the current control settings")
End If
' Modify the properties of the retrieved DCB structure as appropriate.
' WARNING: Make sure to modify the properties according to their supported values.
MyDCB.BaudRate = 9600
MyDCB.ByteSize = 8
MyDCB.Parity = NOPARITY
MyDCB.StopBits = ONESTOPBIT
' Reconfigure COM1 based on the properties of the modified DCB structure.
Success = SetCommState(hSerialPort, MyDCB)
If Success = False Then
Throw New CommException("Unable to reconfigure COM1")
End If
' Retrieve the current time-out settings.
Success = GetCommTimeouts(hSerialPort, MyCommTimeouts)
If Success = False Then
Throw New CommException("Unable to retrieve current time-out settings")
End If
' Modify the properties of the retrieved COMMTIMEOUTS structure as appropriate.
' WARNING: Make sure to modify the properties according to their supported values.
MyCommTimeouts.ReadIntervalTimeout = 0
MyCommTimeouts.ReadTotalTimeoutConstant = 0
MyCommTimeouts.ReadTotalTimeoutMultiplier = 0
MyCommTimeouts.WriteTotalTimeoutConstant = 0
MyCommTimeouts.WriteTotalTimeoutMultiplier = 0
' Reconfigure the time-out settings, based on the properties of the modified COMMTIMEOUTS structure.
Success = SetCommTimeouts(hSerialPort, MyCommTimeouts)
If Success = False Then
Throw New CommException("Unable to reconfigure the time-out settings")
End If
' Write data to COM1.
Console.WriteLine("Writing the following data to COM1: Test")
Success = WriteFile(hSerialPort, Buffer, Buffer.Length, BytesWritten, IntPtr.Zero)
If Success = False Then
Throw New CommException("Unable to write to COM1")
End If
' Read data from COM1.
Success = ReadFile(hSerialPort, Buffer, BytesWritten, BytesRead, IntPtr.Zero)
If Success = False Then
Throw New CommException("Unable to read from COM1")
End If
Catch ex As Exception
Console.WriteLine(Ex.Message)
Finally
' Release the handle to COM1.
Success = CloseHandle(hSerialPort)
If Success = False Then
Console.WriteLine("Unable to release handle to COM1")
End If
End Try
Try
' Parallel port.
Console.WriteLine("Accessing the LPT1 parallel port")
' Obtain a handle to the LPT1 parallel port.
hParallelPort = CreateFile("LPT1", GENERIC_READ Or GENERIC_WRITE, 0, IntPtr.Zero, _
OPEN_EXISTING, FILE_ATTRIBUTE_NORMAL, IntPtr.Zero)
' Verify that the obtained handle is valid.
If hParallelPort.ToInt32 = -1 Then
Throw New CommException("Unable to obtain a handle to the LPT1 port")
End If
' Retrieve the current control settings.
Success = GetCommState(hParallelPort, MyDCB)
If Success = False Then
Throw New CommException("Unable to retrieve the current control settings")
End If
' Modify the properties of the retrieved DCB structure as appropriate.
' WARNING: Make sure to modify the properties according to their supported values.
MyDCB.BaudRate = 9600
MyDCB.ByteSize = 8
MyDCB.Parity = NOPARITY
MyDCB.StopBits = ONESTOPBIT
' Reconfigure LPT1 based on the properties of MyDCB.
Success = SetCommState(hParallelPort, MyDCB)
If Success = False Then
Throw New CommException("Unable to reconfigure LPT1")
End If
' Reconfigure LPT1 based on the properties of the modified DCB structure.
Success = GetCommTimeouts(hParallelPort, MyCommTimeouts)
If Success = False Then
Throw New CommException("Unable to retrieve current time-out settings")
End If
' Modify the properties of the retrieved COMMTIMEOUTS structure as appropriate.
' WARNING: Make sure to modify the properties according to their supported values.
MyCommTimeouts.ReadIntervalTimeout = 0
MyCommTimeouts.ReadTotalTimeoutConstant = 0
MyCommTimeouts.ReadTotalTimeoutMultiplier = 0
MyCommTimeouts.WriteTotalTimeoutConstant = 0
MyCommTimeouts.WriteTotalTimeoutMultiplier = 0
' Reconfigure the time-out settings, based on the properties of the modified COMMTIMEOUTS structure.
Success = SetCommTimeouts(hParallelPort, MyCommTimeouts)
If Success = False Then
Throw New CommException("Unable to reconfigure the time-out settings")
End If
' Write data to LPT1.
' Note: You cannot read data from a parallel port by calling the ReadFile function.
Console.WriteLine("Writing the following data to LPT1: Test")
Success = WriteFile(hParallelPort, Buffer, Buffer.Length, BytesWritten, IntPtr.Zero)
If Success = False Then
Throw New CommException("Unable to write to LPT1")
End If
Catch ex As Exception
Console.WriteLine(Ex.Message)
Finally
' Release the handle to LPT1.
Success = CloseHandle(hParallelPort)
If Success = False Then
Console.WriteLine("Unable to release handle to LPT1")
End If
End Try
Console.WriteLine("Press ENTER to quit")
Console.ReadLine()
End Sub
End Module
When you run the application, you may receive the following
error message:
System.NullReferenceException: Object
reference not set to an instance of an object.
You may receive this
error message because your function declarations are incorrect. This error
message typically occurs when your declarations contain ByVal parameters instead of ByRef parameters.
•
Your application may wait indefinitely when you invoke the ReadFile function. This behavior typically occurs when you set the read
time-outs to zero in the retrieved COMMTIMEOUTS structure. To resolve this issue, modify the properties of the COMMTIMEOUTS structure, as appropriate.
Need More Help? Contact a Support professional by Email, Online or Phone.
Customer Service For non-technical assistance with product purchases, subscriptions, online services, events, training courses, corporate sales, piracy issues, and more.
Newsgroups Pose a question to other users. Discussion groups and Forums about specific Microsoft products, technologies, and services.