Error message when you run hardware inventory on SMS clients that are running Windows XP: "Unknown error encountered processing an instance of class win32_cdromdrive"

Article translations Article translations
Article ID: 906277
Expand all | Collapse all

On This Page

SYMPTOMS

You run hardware inventory on Microsoft Systems Management Server (SMS) clients that are running Microsoft Windows XP with Service Pack 2 (SP2) or Windows XP with Service Pack 1 (SP1). After you do this, an error message that is similar to the following may be logged in the hardware inventory agent client log file (Hinv32.log):
Unknown error encountered processing an instance of class win32_cdromdrive; 80041004 Collection ;(80041004) execute; queryfailed.
Notes
  • The Hinv32.log file is located in the %windir%\Ms\Sms\Logs folder.
  • You experience the symptoms only on client SMS computers that have a CD drive installed.

CAUSE

This problem may occur if the Restrict CD-ROM access to locally logged on users only security policy is enabled on the client computers.

RESOLUTION

A supported hotfix is available from Microsoft. However, this hotfix is intended to correct only the problem that is described in this article. Apply this hotfix only to systems that are experiencing this specific problem. This hotfix might receive additional testing. Therefore, if you are not severely affected by this problem, we recommend that you wait for the next software update that contains this hotfix.

If the hotfix is available for download, there is a "Hotfix download available" section at the top of this Knowledge Base article. If this section does not appear, contact Microsoft Customer Service and Support to obtain the hotfix.

Note If additional issues occur or if any troubleshooting is required, you might have to create a separate service request. The usual support costs will apply to additional support questions and issues that do not qualify for this specific hotfix. For a complete list of Microsoft Customer Service and Support telephone numbers or to create a separate service request, visit the following Microsoft Web site:
http://support.microsoft.com/contactus/?ws=support
Note The "Hotfix download available" form displays the languages for which the hotfix is available. If you do not see your language, it is because a hotfix is not available for that language.

Prerequisites

There are no prerequisites.

Restart requirement

You must restart the computer after you apply this hotfix.

Hotfix replacement information

This hotfix does not replace any other hotfixes.

File information

The English version of this hotfix has the file attributes (or later file attributes) that are listed in the following table. The dates and times for these files are listed in Coordinated Universal Time (UTC). When you view the file information, it is converted to local time. To find the difference between UTC and local time, use the Time Zone tab in the Date and Time tool in Control Panel.
Collapse this tableExpand this table
File nameFile versionFile sizeDateTimePlatformSP requirementService branch
Licdll.dll5.1.2600.1746398,84814-Sep-200502:11x86SP1SP1QFE
Winlogon.exe5.1.2600.1746483,32814-Sep-200502:01x86SP1SP1QFE
Licdll.dll5.1.2600.2759423,93614-Sep-200502:01x86SP2SP2QFE
Winlogon.exe5.1.2600.2759502,78414-Sep-200501:56x86SP2SP2QFE

STATUS

Microsoft has confirmed that this is a problem in the Microsoft products that are listed in the "Applies to" section.

MORE INFORMATION

For more information, click the following article number to view the article in the Microsoft Knowledge Base:
824684 Description of the standard terminology that is used to describe Microsoft software updates

Properties

Article ID: 906277 - Last Review: October 9, 2011 - Revision: 3.0
Keywords: 
kbautohotfix kbqfe kbhotfixserver kbtshoot kbfix kbbug KB906277

Give Feedback

 

Contact us for more help

Contact us for more help
Connect with Answer Desk for expert help.
Get more support from smallbusiness.support.microsoft.com