Article ID: 919168 - Last Review: October 11, 2007 - Revision: 2.7 An IDE device runs in PIO mode instead of in DMA mode after you update the firmware for the device in Windows Server 2003
For a Microsoft Windows XP version of this article, see P2
(http://support.microsoft.com/kb/920918/EN-US/
)
. On This PageSYMPTOMS
After you update the firmware for an IDE device in a computer that is running Microsoft Windows Server 2003, the device runs in Program Input/Output (PIO) mode instead of in Direct Memory Access (DMA) mode. Therefore, the performance of the device may be significantly decreased. CAUSE
This problem occurs if Windows redetects the device immediately after the firmware update, and the device's firmware information has changed. RESOLUTIONService pack informationTo resolve this problem, obtain the latest service pack for Windows Server 2003. For more information, click the following article number to view the article in the Microsoft Knowledge Base:889100
(http://support.microsoft.com/kb/889100/
)
How to obtain the latest service pack for Windows Server 2003 Hotfix informationA supported hotfix is available from Microsoft. However, this hotfix is intended to correct only the problem that is described in this article. Apply this hotfix only to systems that are experiencing this specific problem. This hotfix might receive additional testing. Therefore, if you are not severely affected by this problem, we recommend that you wait for the next software update that contains this hotfix.If the hotfix is available for download, there is a "Hotfix download available" section at the top of this Knowledge Base article. If this section does not appear, contact Microsoft Customer Service and Support to obtain the hotfix. Note If additional issues occur or if any troubleshooting is required, you might have to create a separate service request. The usual support costs will apply to additional support questions and issues that do not qualify for this specific hotfix. For a complete list of Microsoft Customer Service and Support telephone numbers or to create a separate service request, visit the following Microsoft Web site: http://support.microsoft.com/contactus/?ws=support
(http://support.microsoft.com/contactus/?ws=support)
Note The "Hotfix download available" form displays the languages for which the hotfix is available. If you do not see your language, it is because a hotfix is not available for that language.PrerequisitesTo apply this hotfix, your computer must be running one of the following operating systems:
Restart requirementYou must restart your computer after you apply this hotfix.Hotfix replacement informationThis hotfix does not replace any other hotfixes.File informationThe English version of this hotfix has the file attributes (or later file attributes) that are listed in the following table. The dates and times for these files are listed in Coordinated Universal Time (UTC). When you view the file information, it is converted to local time. To find the difference between UTC and local time, use the Time Zone tab in the Date and Time item in Control Panel.Windows Server 2003, 32-bit versionsCollapse this table
Windows Server 2003, x64-based versionsCollapse this table
Windows Server 2003, Itanium-based versionsCollapse this table
STATUSMicrosoft has confirmed that this is a problem in the Microsoft products that are listed in the "Applies to" section. This problem was first corrected in Windows Server 2003 Service Pack 2. MORE INFORMATION
For more information about how to find the input/output (DMA/PIO) settings for a device in Windows XP, click the following article number to view the article in the Microsoft Knowledge Base:
310751
(http://support.microsoft.com/kb/310751/
)
Device settings are hard to find in Windows XP
For more information about the terms that are used in this article, click the following article number to view the article in the Microsoft Knowledge Base:824684
(http://support.microsoft.com/kb/824684/
)
Description of the standard terminology that is used to describe Microsoft software updates Technical support for x64-based versions of Microsoft WindowsYour hardware manufacturer provides technical support and assistance for x64-based versions of Windows. Your hardware manufacturer provides support because an x64-based version of Windows was included with your hardware. Your hardware manufacturer might have customized the installation of Windows with unique components. Unique components might include specific device drivers or might include optional settings to maximize the performance of the hardware. Microsoft will provide reasonable-effort assistance if you need technical help with your x64-based version of Windows. However, you might have to contact your manufacturer directly. Your manufacturer is best qualified to support the software that your manufacturer installed on the hardware.For product information about Microsoft Windows XP Professional x64 Edition, visit the following Microsoft Web site: http://www.microsoft.com/windowsxp/64bit/default.mspx
(http://www.microsoft.com/windowsxp/64bit/default.mspx)
For product information about x64-based versions of Microsoft Windows Server 2003, visit the following Microsoft Web site: http://www.microsoft.com/windowsserver2003/64bit/x64/editions.mspx
(http://www.microsoft.com/windowsserver2003/64bit/x64/editions.mspx)
APPLIES TO
| Other Resources Other Support Sites
CommunityGet Help NowArticle Translations
|






Windows Live
Facebook
Twitter
Linkedin
Digg it
Yahoo
Delicious
StumbleUpon
Yammer
Reddit
Technorati
FriendFeed
Email
Back to the top
