Error message when you connect a portable Windows Vista-based computer to a docking station: "STOP: 0x000000fe"

Article translations Article translations
Article ID: 934374 - View products that this article applies to.
Expand all | Collapse all

On This Page

SYMPTOMS

When you connect a portable Windows Vista-based computer to a docking station, you may receive a Stop error message that resembles the following:
*** STOP: 0x000000fe (0x00000006, parameter2, 0x48676643, 0x00000000)
BUGCODE_USB_DRIVER
This problem occurs if at least one of the following conditions is true:
  • The computer uses a built-in charge-coupled device (CCD) or a built-in card-reader.
  • A digital camera is connected to the computer through a universal serial bus (USB) cable.

RESOLUTION

Service pack information

To resolve this problem, obtain the latest service pack for Windows Vista. For more information, click the following article number to view the article in the Microsoft Knowledge Base:
935791 How to obtain the latest Windows Vista service pack

Hotfix information

A supported hotfix is available from Microsoft. However, this hotfix is intended to correct only the problem that is described in this article. Apply this hotfix only to systems that are experiencing this specific problem. This hotfix might receive additional testing. Therefore, if you are not severely affected by this problem, we recommend that you wait for the next software update that contains this hotfix.

If the hotfix is available for download, there is a "Hotfix download available" section at the top of this Knowledge Base article. If this section does not appear, contact Microsoft Customer Service and Support to obtain the hotfix.

Note If additional issues occur or if any troubleshooting is required, you might have to create a separate service request. The usual support costs will apply to additional support questions and issues that do not qualify for this specific hotfix. For a complete list of Microsoft Customer Service and Support telephone numbers or to create a separate service request, visit the following Microsoft Web site:
http://support.microsoft.com/contactus/?ws=support
Note The "Hotfix download available" form displays the languages for which the hotfix is available. If you do not see your language, it is because a hotfix is not available for that language.

Prerequisites

No prerequisites are required.

Restart requirement

You must restart your computer after you apply this hotfix.

Hotfix replacement information

This hotfix does not replace a previously released hotfix.

File information

The English version of this hotfix has the file attributes (or later file attributes) that are listed in the following table. The dates and times for these files are listed in Coordinated Universal Time (UTC). When you view the file information, it is converted to local time. To find the difference between UTC and local time, use the Time Zone tab in the Date and Time item in Control Panel.
Windows Vista, x86-based versions
Collapse this tableExpand this table
File nameFile versionFile sizeDateTimePlatform
Update.mumNot applicable1,81812-Jun-200710:11Not applicable
Usbvideo.sys6.0.6000.20617132,86412-Jun-200701:22Not applicable
X86_usbvideo.inf_31bf3856ad364e35_6.0.6000.20617_none_2c9b7eddd68ca944.manifestNot applicable1,48712-Jun-200710:12Not applicable
Windows Vista, 64-bit versions
Collapse this tableExpand this table
File nameFile versionFile sizeDateTimePlatform
Amd64_usbvideo.inf_31bf3856ad364e35_6.0.6000.20617_none_88ba1a618eea1a7a.manifestNot applicable1,48912-Jun-200710:17Not applicable
Update.mumNot applicable1,81812-Jun-200710:11Not applicable
Usbvideo.sys6.0.6000.20617167,16812-Jun-200701:52x64

STATUS

Microsoft has confirmed that this is a problem in the Microsoft products that are listed in the "Applies to" section. This problem was first corrected in Windows Vista Service Pack 1.

MORE INFORMATION

The symptoms of a Stop error may vary, depending on the failure options that have been configured in Windows. For more information about how to configure system failure options, click the following article number to view the article in the Microsoft Knowledge Base:
307973 How to configure system failure and recovery options in Windows
For more information, click the following article number to view the article in the Microsoft Knowledge Base:
824684 Description of the standard terminology that is used to describe Microsoft software updates

Properties

Article ID: 934374 - Last Review: May 17, 2008 - Revision: 3.1
APPLIES TO
  • Windows Vista Home Basic 64-bit Edition
  • Windows Vista Home Premium 64-bit Edition
  • Windows Vista Business 64-bit Edition
  • Windows Vista Enterprise 64-bit Edition
  • Windows Vista Ultimate 64-bit Edition
  • Windows Vista Starter
  • Windows Vista Home Basic
  • Windows Vista Home Premium
  • Windows Vista Business
  • Windows Vista Enterprise
  • Windows Vista Ultimate
Keywords: 
kbautohotfix kbvistasp1fix kbbug kbfix kbprb kbexpertiseinter kbwinvistapostrtmfix kbqfe kbhotfixserver KB934374

Give Feedback

 

Contact us for more help

Contact us for more help
Connect with Answer Desk for expert help.
Get more support from smallbusiness.support.microsoft.com