Help and Support

Article ID: 937486 - Last Review: June 8, 2007 - Revision: 1.1

BUG: Error message when you try to configure BizTalk Accelerator for RosettaNet 3.3: "Unexpected exception occurred while configuring [Runtime]"

Expand all | Collapse all

SYMPTOMS

When you try to configure Microsoft BizTalk Accelerator for RosettaNet 3.3, you may receive an error message that resembles the following:
Error Configuration Framework]Feature: [Runtime] Failed to configure with error message [<Exception Message="Unexpected exception occurred while configuring [Runtime]." Source="" HelpID=""><Exception Message="Attempted to read or write protected memory. This is often an indication that other memory is corrupt." Source="Configuration" HelpID="" /></Exception>]

CAUSE

This problem may occur on a computer that is running Windows SharePoint Services.

RESOLUTION

To work around this problem, use the NETBIOS name of the computer as the Web server name when you configure the Runtime feature in BizTalk Accelerator for RosettaNet.

STATUS

Microsoft has confirmed that this is a bug in the Microsoft products that are listed in the "Applies to" section.

APPLIES TO
  • Microsoft BizTalk Accelerator for RosettaNet 3.0 Standard Edition
  • Microsoft BizTalk Accelerator for RosettaNet 3.0 Enterprise Edition
Keywords: 
kbbug kbbtsaccelerators kbbts kbtshoot KB937486

Article Translations