Office Communications Server or Lync Server 2010 Front End Services fail after backend database moveArticle ID: 968100 - View products that this article applies to. SYMPTOMS This problem occurs if one or more of the following conditions are true:
The following Warning event will be logged in the Lync Server 2010 Event log: Log Name: Lync Server Source: LS User Services Date: mm/dd/yyyy hh:mm:ss AM|PM Event ID: 32118 Task Category: (1006) Level: Warning Keywords: Classic User: N/A Computer: server01.contoso.com Description: SQL server cross database chaining option is disabled for either rtc or rtcdyn database. This may be caused by attaching or restoring an existing database. Since this condition causes performance issues, database will not be acquired until the issue is resolved. Back-end Server: server01.contoso.com\lync Database: rtc Connection string of: driver={SQL Server Native Client 10.0};Trusted_Connection=yes;AutoTranslate=no;server=server01.contoso.com\lync;database=rtc; Cause: Check the eventlog description. Resolution: Please enable cross database chaining option (using "sp_dboption '<dbname>', 'db chaining', TRUE") for both rtc and rtcdyn databases. Once this is done, Service will automatically reconnect to the backend. The following Error event will be logged in the Office Communications Server Event log: Log Name: Communications Server Source: OCS Server Date: mm/dd/yyyy hh:mm:ss AM|PM Event ID: 12304 Task Category: (1000) Level: Error Keywords: Classic User: N/A Computer: server01.contoso.com Description: The component Live Communications User Services (application: Default) reported a critical error: code C3EE7D3D (SQL server cross database chaining option is disabled for either rtc or rtcdyn database. This may be caused by attaching or restoring an existing database. Since this condition causes performance issues, service will be stopped and will not start until the problem is resolved. The following error will be displayed by Office Communications Server: Windows could not start the Office Communications Server Front-End on Local Computer. For more information review the System Event Log. If this is a non-Microsoft service, contact the service vendor, and refer to service specific error code -1007780547 CAUSEThis problem occurs if the cross-database chaining option has been disabled for the RTC database and for the RTCDyn database. The cross-database chaining option must always be enabled. However, this option is disabled when you detach and then reattach the databases. RESOLUTIONTo resolve this problem, follow these steps to enable cross-database ownership chaining for the RTC database and for the RTCdyn database:
STATUSMicrosoft
has confirmed that this is a problem in the Microsoft products that are listed
in the "Applies to" section. REFERENCESAnother fix for this issue for Office Communications Server 2007 R2, visit the following Microsoft Website: Description of the update package for Office Communications Server 2007 R2 Database: July, 2009
(http://support.microsoft.com/kb/969834)
PropertiesArticle ID: 968100 - Last Review: April 27, 2012 - Revision: 5.0 APPLIES TO
| Article Translations
|


Back to the top