FIX: The display does not change as expected on a Windows CE 6.0-based video graphics adapter which uses a driver that supports multiple overlay surfaces

Article translations Article translations
Article ID: 968339 - View products that this article applies to.
Expand all | Collapse all

On This Page

SYMPTOMS

A Windows Embedded CE 6.0-based video graphics adapter uses a driver that supports multiple overlay surfaces. When an application calls the UpdateOverlayZOrder method of the IDirectDrawSurface interface to set the Z-order of the overlay surface, the display does not change as expected. Additionally, the pOverlays array that holds the overlay surfaces in the DDRAWI_DIRECTDRAW_GBL structure becomes corrupted. This problem occurs when one of the following flags is used in the UpdateOverlayZOrder method:
  • DDOVERZ_SENDTOBACK
  • DDOVERZ_INSERTINFRONTOF
  • DDOVERZ_INSERTINBACKOF
  • DDOVERZ_SENDTOFRONT

CAUSE

This problem occurs because an index in the pOverlays array in the DDRAWI_DIRECTDRAW_GBL structure is handled incorrectly.

RESOLUTION

Software update information

A supported software update is now available from Microsoft as Windows CE 6.0 Platform Builder Monthly Update (March 2009). You can confirm this by scrolling to the "File information" section of this article. The package file name contains the product version, date, Knowledge Base article number, and processor type. The package file name format is:
Product version-yymmdd-kbnnnnnn-processor type
For example: Wincepb50-060503-kb917590-armv4i.msi is the ARMV4i Windows CE 5.0 Platform Builder fix that is documented in KB article 917590 and that is contained in the May 2006 monthly update. To resolve this problem immediately, click the following article number for information about obtaining Windows CE Platform Builder and core operating system software updates:
837392 How to locate core operating system fixes for Microsoft Windows CE Platform Builder products

Prerequisites

This update is supported only if all previously issued updates for this product have also been installed.

Restart requirement

After you apply this software update, you must perform a clean build of the whole platform. To do this, use one of the following methods:
  • On the Build menu, click Clean, and then click Build Platform
  • On the Build menu, click Rebuild Platform.
You do not have to restart the computer after you apply this software update.

Update replacement information

This update does not replace any other updates.

File information

The English version of this software update package has the file attributes or the later file attributes that are listed in the following table.

Collapse this tableExpand this table
File nameFile sizeDateTime
Wincepb60-090331-kb968339-armv4i.msi1,439,23202-Apr-200921:18
Wincepb60-090331-kb968339-mipsii.msi1,412,60802-Apr-200921:18
Wincepb60-090331-kb968339-mipsii_fp.msi1,412,60802-Apr-200921:18
Wincepb60-090331-kb968339-mipsiv.msi1,426,43202-Apr-200921:18
Wincepb60-090331-kb968339-mipsiv_fp.msi1,426,43202-Apr-200921:18
Wincepb60-090331-kb968339-sh4.msi1,408,00002-Apr-200921:18
Wincepb60-090331-kb968339-x86.msi1,310,72002-Apr-200921:18


The English version of this software update package has the file attributes (or later file attributes) that are listed in the following table. The dates and times for these files are listed in Coordinated Universal Time (UTC). When you view the file information, it is converted to local time. To find the difference between UTC and local time, use the Time Zone tab in the Date and Time item in Control Panel.
Collapse this tableExpand this table
File nameFile sizeDateTimePath
Windows embedded ce 6.0_update_kb968339.htm7,68002-Apr-200918:59090331_kb968339
Ddcore.lib1,735,54419-Mar-200923:12Public\Common\Oak\Lib\Armv4i\Debug
Ddcore.lib1,158,05819-Mar-200923:12Public\Common\Oak\Lib\Armv4i\Retail
Ddcore.lib1,709,44019-Mar-200923:13Public\Common\Oak\Lib\Mipsii\Debug
Ddcore.lib1,136,57619-Mar-200923:12Public\Common\Oak\Lib\Mipsii\Retail
Ddcore.lib1,709,53219-Mar-200923:13Public\Common\Oak\Lib\Mipsii_fp\Debug
Ddcore.lib1,136,74019-Mar-200923:13Public\Common\Oak\Lib\Mipsii_fp\Retail
Ddcore.lib1,738,46619-Mar-200923:14Public\Common\Oak\Lib\Mipsiv\Debug
Ddcore.lib1,154,36219-Mar-200923:14Public\Common\Oak\Lib\Mipsiv\Retail
Ddcore.lib1,738,55819-Mar-200923:15Public\Common\Oak\Lib\Mipsiv_fp\Debug
Ddcore.lib1,154,52619-Mar-200923:14Public\Common\Oak\Lib\Mipsiv_fp\Retail
Ddcore.lib1,582,12619-Mar-200923:15Public\Common\Oak\Lib\Sh4\Debug
Ddcore.lib1,082,55219-Mar-200923:15Public\Common\Oak\Lib\Sh4\Retail
Ddcore.lib1,488,08419-Mar-200923:11Public\Common\Oak\Lib\X86\Debug
Ddcore.lib1,015,20019-Mar-200923:11Public\Common\Oak\Lib\X86\Retail

STATUS

Microsoft has confirmed that this is a problem in the Microsoft products that are listed in the "Applies to" section.

MORE INFORMATION

For more information about Overlay Z-orders, visit the following Microsoft Developer Network (MSDN) Web site:
http://msdn.microsoft.com/en-us/library/aa911040.aspx
For more information about the UpdateOverlayZOrder method, visit the following MSDN Web site:
http://msdn.microsoft.com/en-us/library/aa921158.aspx
For more information about software update terminology, click the following article number to view the article in the Microsoft Knowledge Base:
824684 Description of the standard terminology that is used to describe Microsoft software updates

Properties

Article ID: 968339 - Last Review: October 7, 2011 - Revision: 2.0
APPLIES TO
  • Windows Embedded CE 6.0
Keywords: 
kbexpertiseadvanced kbsurveynew kbqfe KB968339

Give Feedback

 

Contact us for more help

Contact us for more help
Connect with Answer Desk for expert help.