Select the product you need help with
The SharePoint Products and Technologies Configuration Wizard fails after you install any cumulative update or service pack for Project Server 2007 that was released in October 2008 or laterArticle ID: 971217 - View products that this article applies to. SYMPTOMSAfter you install any cumulative update or service pack for
Microsoft Office Project Server 2007 that was released in October 2008 or later, the
SharePoint Products and Technologies Configuration Wizard fails. Additionally,
the following error message logged in the Upgrade.log file: “Microsoft.Office.Project.Server.Upgrade.ReportingDatabaseUpgrader_12_1_153_0.Upgrade()” The DELETE statement conflicted with the REFERENCE constraint "FK_MSP_TimesheetLine_TaskNameUID". The conflict occurred in database "TaskConsistency_<instance_name>_Reporting", table "dbo.MSP_TimesheetLine", column 'TaskNameUID'. The statement has been terminated. at System.Data.SqlClient.SqlConnection.OnError(SqlException exception, Boolean breakConnection) at System.Data.SqlClient.TdsParser.ThrowExceptionAndWarning(TdsParserStateObject stateObj) at System.Data.SqlClient.TdsParser.Run(RunBehavior runBehavior, SqlCommand cmdHandler, SqlDataReader dataStream, BulkCopySimpleResultSet bulkCopyHandler, TdsParserStateObject stateObj) at System.Data.SqlClient.SqlCommand.RunExecuteNonQueryTds(String methodName, Boolean async) at System.Data.SqlClient.SqlCommand.InternalExecuteNonQuery(DbAsyncResult result, String methodName, Boolean sendToPipe) at System.Data.SqlClient.SqlCommand.ExecuteNonQuery() at Microsoft.Office.Server.Data.SqlSession.ExecuteScript(TextReader textReader, Int32 commandTimeout) at Microsoft.SharePoint.Upgrade.SPDatabaseAction.ExecuteSql(String sql, Int32 commandTimeout) at Microsoft.SharePoint.Upgrade.SPDatabaseAction.ExecuteSql(String sql)at Microsoft.Office.Project.Server.Upgrade.ReportingDatabaseUpgrader_12_1_153_0.Upgrade() at Microsoft.SharePoint.Upgrade.SPActionSequence.Upgrade() CAUSE This issue occurs because of a very specific condition in the
reporting database. In a very small number of cases, there may be duplicate
records in the reporting database. These duplicate records can cause the SharePoint Products and
Technologies Configuration Wizard to fail. RESOLUTIONBefore you install any Project Server 2007 cumulative update or service pack that is
released in October 2008 or later, use the following script to check for the
condition in the reporting database. Notes
STATUSMicrosoft
has confirmed that this is a problem in the Microsoft products that are listed
in the "Applies to" section. MORE INFORMATIONIf this is an issue for your deployment, it will only be an
issue one time. Therefore, you do not have to run this script if either of the
following conditions is true:
PropertiesArticle ID: 971217 - Last Review: September 18, 2011 - Revision: 5.0
|


Back to the top