Article ID: 972107 - Last Review: September 28, 2009 - Revision: 3.0 Error event ID 5 is logged in the System log on a computer that uses the iSCSI Software Initiator to connect to an iSCSI target device
On This PageSYMPTOMSOn a computer that uses the iSCSI Software Initiator to connect to an iSCSI target device, the following Error event may be logged in the System log periodically or when the computer starts: Log Name: System
Source: iScsiPrt Event ID: 1 Task Category: None Level: Error Keywords: Classic Description: Initiator failed to connect to the target. Target IP address and TCP Port number are given in dump data. Log Name: System Source: iScsiPrt Event ID: 5 Task Category: None Level: Error Keywords: Classic Description: Failed to setup initiator portal. Error status is given in the dump data. Log Name: System
Source: iScsiPrt Event ID: 70 Task Category: None Level: Error Keywords: Classic Description: Error occurred when processing iSCSI logon request. The request was not retried. Error status is given in the dump data. Log Name: System
Source: MSiSCSI Event ID: 113 Task Category: None Level: Warning Keywords: Classic Description: iSCSI discovery via SendTargets failed with error code 0xefff0003 to target portal *xxx.xxx.xxxx.xxxx 0003260 Root\ISCSIPRT\0000_0 . Note This issue may occur in all versions of Windows Vista, Windows 7, Windows Server 2008, and Windows Server 2008 R2. CAUSEThis issue occurs for one or more of the following reasons. Cause 1An iSCSI target device that is listed on the Favorite Targets tab of the iSCSI Initiator is no longer accessible. This may occur if the iSCSI target device name is changed, if the IP address is changed, or if the iSCSI target device is removed from the network.Cause 2The iSCSI target device has reached its limit for the number of incoming connections.Cause 3A transient network issue temporarily prevented connectivity to the iSCSI target device.Cause 4The network stack is not fully prepared when the initiator was trying to connect to persistent targets. The initiator will retry to connect. When the network stack is fully prepared, connection should be successfully established.RESOLUTIONIf you receive this error when the iSCSI target device that is listed on the Favorite Targets tab no longer exists, you can resolve this issue by removing the iSCSI target device from the list of favorite targets. If you receive this error, and you cannot access an iSCSI target device that is still configured on the network, make sure that the client computer has network connectivity to the iSCSI target and make sure that name resolution is working correctly. If you have successfully connected to your iSCSI target device despite this error, it indicates that the connectivity issue was temporary. Therefore, you can safely ignore this Error event. APPLIES TO
| Other Resources Other Support Sites
CommunityGet Help NowArticle Translations |






Windows Live
Facebook
Twitter
Linkedin
Digg it
Yahoo
Delicious
StumbleUpon
Yammer
Reddit
Technorati
FriendFeed
Email
Back to the top