On This PageSYMPTOMS
When you try to replicate a database on a computer running Microsoft
Windows NT, you may receive the following error message:
An application error has occurred and an application error log is being generated.
MSACCESS.exe Exception: access violation (0xc0000005), Address: 0x77f7d357
This program has performed an illegal operation
and will be shut down.
MSACCESS.EXE caused a stack fault in module KERNEL32.DLL at 0137:bff783df. Heap block at 114fa58 modified at 114fc60 past requested size of 200 CAUSE
The computer has more than 128 network shares. As a result, the Microsoft
Replication Library fails while loading and generates one of the errors
described in the "Symptoms" section. The Microsoft Jet database engine
loads this library only when you use replication.
RESOLUTION
To prevent this problem, either reduce the number of shares or avoid using
Jet replication on the computer.
STATUS
Microsoft has confirmed this to be a problem in Microsoft Access versions
7.0 and 97.