Article ID: 250498 - Last Review: March 1, 2007 - Revision: 3.2 Setup Manager Incorrectly Writes the OEMPnpDriversPath Line in the Sysprep.inf FileThis article was previously published under Q250498 SYMPTOMS
When you create a Sysprep.inf file using the Setup Manager tool, the OemPnpDriversPath registry key may be written incorrectly. The Graphical portion of Sysprep (referred to as Mini-setup Wizard) is not interrupted, but devices requiring Original Equipment Manufacturer (OEM) drivers are not installed. CAUSE
This issue can occur if the OemPnpDriversPath registry key is written to the wrong path.
RESOLUTION
To work around this issue, edit the Sysprep.inf file and change the OemPnpDriversPath line to the following:
OemPnpDriversPath = "Drivers"
STATUS
Microsoft has confirmed this to be a problem in Microsoft Windows 2000.
MORE INFORMATION
The OemPnpDriversPath registry key is used to locate Plug and Play (PnP) drivers supplied by vendors to be installed during setup.
When you create the Sysprep.inf file using Setup Manager, you can specify the location of Plug and Play drivers on the Additional Files and Folders page. When you select the location of these files, such as c:\drivers, the OemPnpDriversPath value data is written as follows:
OemPnpDriversPath = C:\drivers
Windows automatically prepends the value data with %SystemDrive%, so the incorrect path %SystemDrive%\C:\drivers is written to the following registry key:
HKLM\Software\Microsoft\Windows\CurrentVersion\DevicePath