Article ID: 272978 - Last Review: October 31, 2006 - Revision: 3.2 Applying a Hisecweb.inf template to a Web server prevents the Routing and Remote Access Service from starting in Windows 2000This article was previously published under Q272978 SYMPTOMS
If you apply a Hisecweb.inf security template to Microsoft Windows 2000 Server-based computer, the Routing and Remote Access Service is prevented from starting. When the service tries to start, the following error message is logged in the System log on the server:
Source: Service Control Manager Event ID: 7024 Description: The Routing and Remote Access service terminated with service-specific error 711. You do not have the required permissions to view the properties. CAUSE
This behavior may occur because the Routing and Remote Access Service cannot start. This service cannot start if the Remote Access Connection Manager service and the Telephony service are disabled. The Hisecweb.inf security template typically disables the following services by setting the Startup Type to Disabled:
RESOLUTION
To resolve this behavior, use the Services Administrative tool to set the Startup Type of these services to Automatic. After you have configured these settings, restart the Routing and Remote Access Service.
STATUS
This behavior is by design.
MORE INFORMATIONTo obtain
the Hisecweb.inf security template, visit the following Microsoft Web site: http://www.microsoft.com/downloads/details.aspx?FamilyID=564a8b50-17d7-46f1-9a22-d9637bae9547&displaylang=en
(http://www.microsoft.com/downloads/details.aspx?FamilyID=564a8b50-17d7-46f1-9a22-d9637bae9547&displaylang=en)
| Article Translations
|
Back to the top