Article ID: 284013 - Last Review: May 14, 2007 - Revision: 2.4 Error Message: The Command REGSVR32 /S CDOWFEVT.DLL FailedThis article was previously published under Q284013 SYMPTOMS
If you install SharePoint Portal Server, the installation may fail, and the following error message may be logged in the Exchange Server Setup Progress.log file that is located in the root of the drive that you installed SharePoint Portal Server to:
The command
regsvr32 /s cdowfevt.dll
failed, returning error code 5 (Access is denied). ScCreateProcess (J:\Admin\Src\Libs\Exsetup\Hiddenw1.cxx:1763) Error code 0XC103798A (31114): An internal component has failed. CAUSE
This issue can occur if the COM+ component service is not installed properly.
RESOLUTION
To resolve this issue, first confirm that the problem is related to COM+:
For additional information about how to reset the COM+ service, click the article number below to view the article in the Microsoft Knowledge Base: 246499
(http://support.microsoft.com/kb/246499/EN-US/
)
PRB: COM+ Setup Problems While Upgrading to Windows 2000
| Article Translations
|
Back to the top