Article ID: 72302 - Last Review: November 26, 2003 - Revision: 3.0 Specifying A20 Handlers with HIMEM.SYS /M in MS-DOSThis article was previously published under Q72302 SUMMARY
MS-DOS version 5.0 includes HIMEM.SYS version 2.77. MS-DOS version 6.0
includes HIMEM.SYS version 3.07. MS-DOS versions 6.2, 6.21, and 6.22
include HIMEM.SYS version 3.10. These versions include an A20 handler for
the following computers that can be used with the /M: or /MACHINE switch:
CODE Number A20 Handler ---- ------ ----------- at 1 IBM PC/AT ps2 2 IBM PS/2 pt1cascade 3 Phoenix Cascade BIOS hpvectra 4 HP Vectra (A and A+) att6300plus 5 AT&T 6300 Plus acer1100 6 Acer 1100 toshiba 7 Toshiba 1600 and 1200XE wyse 8 Wyse 12.5 MHz 286 tulip 9 Tulip SX zenith 10 Zenith ZBIOS at1 11 IBM PC/AT at2 12 IBM PC/AT (alternative delay) css 12 CSS Labs at3 13 IBM PC/AT (alternative delay) philips 13 Philips fasthp 14 HP Vectra ibm7552 15 IBM 7552 Industrial Computer bullmicral 16 Bull Micral 60 dell 17 Dell XBIOS NOTE: In the above list, the device driver should detect the correct handler to use. The following computers may need the corresponding switch added to the CONFIG.SYS file: System Switch ------ ------ Bull Micral 60 /machine:16 COMPUADD 386 systems /machine:1 or /machine:8 Datamedia 386/486 /machine:2 Hitachi HL500C /machine:8 Intel 301z or 302 /machine:8 JDR 386/33 /machine:1 Toshiba 5100 /machine:7 UNISYS PowerPort /machine:2 MORE INFORMATION
The /M switch specifies which hardware the computer is using. If the
wrong switch is used, HIMEM.SYS may not load properly or the system
may hang. For more information, query on the following words:
HIMEM and /M
APPLIES TO
| Article Translations
|

Back to the top