SYMPTOMS

When a client disconnects from a RAS server, the DTR line on the Digiboard COM port may not return. Because the modem is not reset, no additional calls can come in on that port. If a client attempts to dial in, the modem picks up the line, but the RAS server does not respond. As a result, the client receive a 640 error message. The RAS server does not log any errors in the event log, but the RAS Administrators tool show that the port has been disconnected and is not ready.

These symptoms will appear only after the RAS server has been in operation for some time. Stress tests indicate that several hundred inbound calls are needed to produce the problem.

Back to the top

CAUSE

There is a problem in the Digiboard DIGIFEP5.SYS driver.

Back to the top

STATUS

Microsoft has confirmed this to be a problem Windows NT version 3.5.

Back to the top


APPLIES TO
Microsoft Windows NT Server 3.5
Microsoft Windows NT Workstation 3.5
Microsoft Windows NT Advanced Server 3.1

Back to the top

Keywords: 
KB132111

Back to the top