You may receive a page fault error message when Setup is detecting the
Future Domain SCSI controller in your computer. You may receive this error
message even if you do not have a Future Domain SCSI controller installed
in your computer.
Back to the top
386Max software is installed. This software makes the Adaptec ROM region
read-only. When Setup tries to write to the region, the error occurs. Note
that this error occurs only when you are running Setup from MS-DOS. The
problem does not occur if you run Setup from Windows or Windows for
Workgroups in 386 enhanced mode.
Back to the top
To work around this problem, use either of the following methods:
| • | Quit Setup, unload the 386Max software, and then run Setup again.
|
| • | Quit Setup, and then run Setup from Windows or Windows for Workgroups
version 3.x in 386 enhanced mode instead of from MS-DOS.
|
Back to the top