How to send to the serial port by using Mscomm32.ocx
This article was previously published under Q139526 On This PageSUMMARY
This article describes the settings necessary to send data to the serial
port by using Mscomm32.ocx. Mscomm32.ocx ships with Microsoft Visual FoxPro Professional
Edition. It can be used on computers that are running Microsoft Windows 95 and later versions of Windows. MORE INFORMATION
The most frequently used properties to send data to the serial port using
the mscomm control are as follows:
CommPortThe CommPort property specifies the communications port number. A numeric property that corresponds to the Comm port. By default, this property is set to 1 corresponding to com1. Valid values are 1, 2, 3, or 4 depending on the serial ports installed on the computer and their configuration.SettingsThe Settings property configures the baud rate, parity, data bits, and stop bits for the serial port. The Settings property is a character string that contains individual comma-separated values. By default, the Settings property is as follows: 9600,N,8,1 This property corresponds to 9600 baud, no parity, 8 data bits, and 1 stop bit.
The following baud rate values are valid: 110, 300, 600, 1200, 2400, 4800, 9600 (default), 14400, 19200, 28800, 38400, 56000, 57600, 115200, 128000, 256000. PortOpenThe PortOpen property specifies a logical value that controls whether or not the serial port is open and active. Once the previous properties are set to begin using the serial port, you can set this property to true.OutputThe Output property is assigned the string of characters to be sent to the serial port. To output the string "Hello World" to the serial port after the previous properties are set, use the following command:
Other properties that may be also be needed depending on the application
are as follows:
CommEventThe CommEvent property contains a value that represents the most recent communications event or errors.SthresholdThe Sthreshold property specifies the minimum number of characters in the output buffer that are sent.OutBufferCountThe OutBufferCount control returns the number of characters waiting in the transmit buffer. This should always be zero if the Sthreshold property is zero. Setting the OutBufferCount property to zero will clear the transmit buffer.OutBufferSizeThe OutBufferSize property specifies the size of the transmit buffer. By default, this buffer is 512 bytes. The larger the transmit buffer, the less memory available to other applications. Slow baud rates and large text strings written to the serial port may mean you need to make this value larger.Following is a sample that shows how to set up the comm control and dial the phone number 555-1234 by using the standard Hayes Modem commands. Note If you use this in an application and then distribute the application by using the Visual FoxPro Setup Wizard, you may see the following error when you run the application:
Program Error OLE error code 0x80040112: Appropriate license for this class not found.
If this error occurs, see the following article in the Microsoft Knowledge Base:
192693 (http://support.microsoft.com/kb/192693/) License error with ActiveX control added at run-time
APPLIES TO
| Article Translations
|