WMI-Activity Event 5858 logged frequently with ResultCode 0x80041032
This article provides a resolution to solve the WMI-Activity event ID 5858 that's logged with ResultCode = 0x80041032 in Windows Server 2012 R2.
Applies to: Windows Server 2012 R2
Original KB number: 3124914
Symptoms
When using Windows Server 2012 R2 with applications that issue WMI queries using IWbemServices:ExecQuery
, the administrator may observe the following event in Event Viewer:
Log Name: Microsoft-Windows-WMI-Activity/Operational
Source: WMI-Activity
Event ID: 5858
Level: Error
Id = {guid}; ClientMachine = <computer>; User = <user>; ClientProcessId = <process ID>; Component = Unknown; Operation = Start IWbemServices::ExecQuery - <WMI namespace>: <Select Query Statement>; ResultCode = 0x80041032; PossibleCause = Unknown
where 0x80041032 indicates WBEM_E_CALL_CANCELLED.
Note
This event can occur with many different ResultCode values. The problem described in this article only applies when ResultCode = 0x80041032 (WBEM_E_CALL_CANCELLED)
.
Cause
WMI-Activity Error 5858 with ResultCode = 0x80041032 (WBEM_E_CALL_CANCELLED) indicates that the WMI caller has successfully issued IWbemServices:ExecQuery
, but has released the IWbemContext
object before retrieving the full result set using the IEnumWbemClassObject::Next
method. If the WMI service is still holding data for the client when the client terminates the link (by releasing the IWbemContext
object), this event will be logged.
This error can happen if the WMI application calls IEnumWbemClassObject::Next
with a timeout value (lTimeout) that is not long enough to retrieve the object being queried, and is not checking for a return code of WBEM_S_TIMEDOUT (0x40004)
in order to issue the request again.
Resolution
The WMI client application should be modified to issue calls to IEnumWbemClassObject::Next
to retrieve the full result set, before releasing the IWbemContext object. If no objects are received, make sure that the timeout value (lTimeout) is greater than 0 and that WBEM_S_TIMEDOUT (0x40004)
is not being returned.
More information
For more information, see:
IEnumWbemClassObject interface
Note
The sample code included at the end of this page shows
IEnumWbemClassObject::Next
being called with a timeout value (lTimeout) of 0, and is not checking for the WBEM_S_TIMEDOUT error.
Data collection
If you need assistance from Microsoft support, we recommend you collect the information by following the steps mentioned in Gather information by using TSS for User Experience issues.
Feedback
https://aka.ms/ContentUserFeedback.