FIX: TI web application encounters exception and hang issues

Applies to: Host Integration Server 2016

Symptoms


When you use a Transaction Integrator (TI) application thatuses SNA LU 6.2 connection to the mainframe, the application may hang and the following error may occur:
HISMSNA0015The SNATransport encountered an error calling internal method CMALLC whenprocessing method <MethodName>, LUName <LUName>. Details: Aninternal error occurred during processing of TP Started, error code = 4592.

Cause


The error occurs under certaincircumstances where a TP_ENDED command is not issued. This results in an increasingnumber of active TP sessions. When 15,000active TP sessions is reached, this error will be reported. 

Status


Microsoft has confirmed that this is a problem in the Microsoft products that are listed in the "Applies to" section. 

Resolution


This issue is fixed in the following cumulative update for Host Integration Server:

References


Learn about the terminology that Microsoft uses to describe software updates.