Hotfix KB2899563 for Access 2013 December 9, 2014 (Access-x-none.msp)

This article describes the issues that are fixed in the Microsoft Access 2013 hotfix package that is dated December 9, 2014. Click the "Hotfix Download Available" button to get the hotfix.

Issue that this hotfix package fixes

When you work with a web app in Access 2013, you may frequently receive the following error message:
An error occurred in the client while attempting to communicate with the server <URL>. Please contact your system administrator or technical support.
BUG #: 3483641 (Office15)

Cause

When Access 2013 sends a request to Access Services in SharePoint, there is a default time that Access 2013 waits for a response from the server. The default time varies, depending on the operation that is being executed. When web apps are large and complex, the processing time on the server may take longer than the time that is allocated by the time-out, and Access 2013 may throw this error message. In this scenario, the server may still be processing without error, and will eventually return a successful response, but Access 2013 has stopped waiting.

How to get the hotfix

A supported hotfix is available from Microsoft. However, this hotfix is intended to correct only the problem that is described in this article. Apply this hotfix only to systems that are experiencing the problem described in this article. This hotfix might receive additional testing. Therefore, if you are not severely affected by this problem, we recommend that you wait for the next software update that contains this hotfix.

If the hotfix is available for download, there is a "Hotfix Download Available" section at the top of this Knowledge Base article. If this section does not appear, contact Microsoft Customer Service and Support to obtain the hotfix.

Note If additional issues occur or if any troubleshooting is required, you might have to create a separate service request. The usual support costs will apply to additional support questions and issues that do not qualify for this specific hotfix. For a complete list of Microsoft Customer Service and Support telephone numbers or to create a separate service request, visit the following Microsoft website: Note The "Hotfix Download Available" form displays the languages for which the hotfix is available. If you do not see your language, it is because a hotfix is not available for that language.

Hotfix information

Registry information

Important
Follow the steps in this section carefully. Serious problems might occur if you modify the registry incorrectly. Before you modify it, back up the registry for restoration in case problems occur.


After you install the hotfix package, depending on when you receive the message, you may add the corresponding registry keys to increase the time-out under the following registry subkey:
HKEY_CURRENT_USER\Software\Microsoft\Office\15.0\Access\Settings
If the attempted operation was one of the following:
  • Creating an app package
  • Creating an object
Follow these steps to create a DWORD registry entry named "AccWebSaveAsPackageTimeout" and set its value to 120000 (decimal.) If the issue persists, try increasing the value or contacting technical support.


If the attempted operation was one of the following:
  • Hydrating, or opening an Access web app in the Access client
Follow these steps to create a DWORD registry entry named "AccAppHydrateOperationsTimeout" and set its value to 480000 (decimal.) If the issue persists, try increasing the value or contacting technical support.


If the attempted operation was one of the following:
  • Opening an object
  • Updating an object
  • Renaming an object
  • Deleting an object
Follow these steps to create a DWORD registry entry named "AccAppObjectOperationsTimeout" and set its value to 60000 (decimal.) If the issue persists, try increasing the value or contacting technical support.


If the attempted operation was one of the following:
  • Creating an app
  • Importing data
Follow these steps to create a DWORD registry entry named "AccAppCreateImportTimeout" and set its value to 240000 (decimal.) If the issue persists, try increasing the value or contacting technical support.


Prerequisites

To install this hotfix package, you must have Access 2013 installed.

Restart requirement

You do not have to restart the computer after you apply this hotfix.

Hotfix replacement information

This hotfix does not replace a previously released hotfix.