SYMPTOMS
SCS data streams that contain DBCS (Double Byte Character Set) codes mayprint incorrectly.
CAUSE
When the last byte in a segment is a DBCS high byte and the first bytein the next segment is a DBCS Low byte, the Print Server translates thepair of DBCS bytes into two SBCS bytes.
STATUS
Microsoft has confirmed this to be a problem in SNA Server versions 3.0,3.0SP1, 3.0SP2 and 4.0.

This problem was corrected in the latest SNA Server versions 3.0 and 4.0U.S. Service Packs. For information on obtaining these Service Packs,query on the following word in the Microsoft Knowledge Base (without thespaces):