SYMPTOMS
When you install Windows NT on an IBM ThinkPad 760EL or XL, along with aSelectaDock II docking station and a 3COM 3c509 card, autodetection of thenetwork adapter fails.
CAUSE
The cause is that the SelectaDock II docking station has a new PCI-to-PCIbridge that uses I/O address 100-110, which is also the default address ofthe 3C509 card. When the detection software does not see a 3C509 card atI/O address 100-100, it assumes there are no cards in the computer and doesnot continue looking for them at different addresses.
RESOLUTION
To resolve this problem, obtain the latest service pack for Windows NT 4.0 or Windows NT Server 4.0, Terminal Server Edition. For additional information, click the following article number to view the article in theMicrosoft Knowledge Base:
152734 How to Obtain the Latest Windows NT 4.0 Service Pack

STATUS
Microsoft has confirmed that this is a problem in Windows NT 4.0 and Windows NT Server 4.0, Terminal Server Edition. This problem was first corrected in Windows NT 4.0 Service Pack 4.0 and Windows NT Server 4.0, Terminal Server Edition Service Pack 4.
Properties

Article ID: 186217 - Last Review: 10/08/2013 02:51:03 - Revision: 1.3

Microsoft Windows NT Server 4.0, Terminal Server Edition, Microsoft Windows NT Server 4.0 Standard Edition, Microsoft Windows NT Server 4.0 Enterprise Edition, Microsoft Windows NT Workstation 4.0 Developer Edition

  • kbnosurvey kbarchive kbhotfixserver kbqfe kbbug kbfix kbqfe KB186217