BUG: Datagram MSRPC in Infinite Loop When Making DCOM Activation Calls to HPUX 9.x Server

This article was previously published under Q216432
This article has been archived. It is offered "as is" and will no longer be updated.
SYMPTOMS
When the client does a remote activation on a HPUX9.x server, the client-side datagram MSRPC runtime goes into an infinite loop.
CAUSE
This is a bug in HPUX 9.x that returns a request packet with an incorrect activity UUID field. Specifically the TimeHiAndVersion field of the UUID is not byte swapped.
RESOLUTION
To resolve this problem, obtain the latest service pack for Microsoft Windows NT version 4.0. For additional information, click the following article number to view the article in theMicrosoft Knowledge Base:
152734 How to Obtain the Latest Windows NT 4.0 Service Pack
STATUS
HPUX 10.x system has fixed the bug. This problem was first corrected in Windows NT 4.0 Service Pack 5.