FIX: DTS Designer Fails with Unspecified Error When Adding Table to DTS Query Designer Window

This article was previously published under Q248420
This article has been archived. It is offered "as is" and will no longer be updated.
BUG #: 56435 (SQLBUG_70)
SYMPTOMS
The Data Transformation Services (DTS) Designer Fails with the following error when adding a table to the DTS Query Designer Window:
Unspecified error
This error did not occur prior to Service Pack 1.
CAUSE
DTS fails with an "Unspecified error" error when using IBM's Client Access Driver to request heterogeneous schema information. In SQL Server 7.0 Service Pack 1, SQL Server began setting the provider specific initialization properties. These properties were not being set correctly for IBM's Client Access Driver.
STATUS
Microsoft has confirmed this to be a problem in SQL Server 7.0. This problem has been corrected in U.S. Service Pack 2 for Microsoft SQL Server 7.0. For more information, click the following article number to view the article in the Microsoft Knowledge Base:
254561 INF: How to Obtain Service Pack 2 for Microsoft SQL Server 7.0 and Microsoft Data Engine (MSDE) 1.0
For more information, contact your primary support provider.