You are currently offline, waiting for your internet to reconnect

Sequencing AutoCAD 2008 on Windows 7 x86 computers fails when installing to Q:\

SYMPTOMS
When sequencing AutoCAD 2008 on x86 Computers running Windows 7, you cannot install to Q:\. The following error is received:

Invalid Path Q:\AutoCAD2008, please select another install path
CAUSE
This can occur if the Q:\ drive is a symbolic link (SymLink) and not a physical partition. AutoCAD does not support SymLinked drives for native or virtual installations.
RESOLUTION
Create a physical partition for the Q drive (or the equivalent drive letter used by the App-V client) and sequence to that partition instead.
MORE INFORMATION
appv, app-v, autocad, symlink, invalid path, autocad 2008, sequencing, sequence, 4.6 SP1, application virtualization
Note This is a "FAST PUBLISH" article created directly from within the Microsoft support organization. The information contained herein is provided as-is in response to emerging issues. As a result of the speed in making it available, the materials may include typographical errors and may be revised at any time without notice. See Terms of Use for other considerations.