You are currently offline, waiting for your internet to reconnect

Wizard generates a clock skew error when you configure a Microsoft Intune subscription in Configuration Manager

Symptoms
When you try to log in during Microsoft Intune setup in System Center Configuration Manager, you may receive the following error message:

The security timestamp is invalid because its creation time ('2013-01-14T11:39:24.628Z') is in the future. Current time is '2013-01-14T11:32:13.572Z' and allowed clock skew is '00:05:00'

Cause
This issue may occur if the time on the target Windows Server 2012 computer is five minutes or more behind the time on the Microsoft Intune login servers. 
Resolution
To fix this issue, confirm that the Windows Server 2012 computer has the correct time. We recommend that you sync the time with an Internet time server or to change the time on the Windows Server 2012 computer to be closer to the time on the Intune servers.
More information
For more information, see the following Microsoft Knowledge Base article:

816042 How to configure an authoritative time server in Windows Server 

This issue may occur with ConfigMgr 2012 as well as ConfigMgr 2012 R2.
Properties

Article ID: 3117662 - Last Review: 11/16/2015 06:24:00 - Revision: 1.0

Microsoft Intune, Microsoft System Center 2012 Configuration Manager, Microsoft System Center 2012 Configuration Manager Service Pack 1, Microsoft System Center 2012 Configuration Manager Service Pack 2, Microsoft System Center 2012 R2 Configuration Manager, Microsoft System Center 2012 R2 Configuration Manager Service Pack 1