You are currently offline, waiting for your internet to reconnect

BUG: Error message when you try to configure BizTalk Accelerator for RosettaNet 3.3: "Unexpected exception occurred while configuring [Runtime]"

SYMPTOMS
When you try to configure Microsoft BizTalk Accelerator for RosettaNet 3.3, you may receive an error message that resembles the following:
Error Configuration Framework]Feature: [Runtime] Failed to configure with error message [<Exception Message="Unexpected exception occurred while configuring [Runtime]." Source="" HelpID=""><Exception Message="Attempted to read or write protected memory. This is often an indication that other memory is corrupt." Source="Configuration" HelpID="" /></Exception>]
CAUSE
This problem may occur on a computer that is running Windows SharePoint Services.
RESOLUTION
To work around this problem, use the NETBIOS name of the computer as the Web server name when you configure the Runtime feature in BizTalk Accelerator for RosettaNet.
STATUS
Microsoft has confirmed that this is a bug in the Microsoft products that are listed in the "Applies to" section.
Properties

Article ID: 937486 - Last Review: 06/08/2007 18:37:40 - Revision: 1.1

Microsoft BizTalk Accelerator for RosettaNet 3.0 Standard Edition, Microsoft BizTalk Accelerator for RosettaNet 3.0 Enterprise Edition

  • kbbug kbbtsaccelerators kbbts kbtshoot KB937486
Feedback