You are currently offline, waiting for your internet to reconnect

Some interchanges are suspended if you use the EDI receive pipeline to receive multiple interchanges that are included in a single EDI message in BizTalk Server 2006 R2 (972530)

Consider the following scenario in BizTalk Server 2006 R2:
  • You use the default Electronic Data Interchange (EDI) Receive pipeline to receive EDI documents from your trading partners.
  • The EDI document contains multiple interchanges.
  • Among the multiple interchanges, the segment terminator in one interchange differs from the segment terminator in the next interchange.
In this scenario, one interchange is processed successfully. However, the next interchange is suspended. If you resume the suspended interchange, the suspended interchange may be processed successfully if the interchange is valid.
This problem occurs because of an error in the EDI components in BizTalk Server 2006 R2.

Hotfix information

A supported hotfix is available from Microsoft. However, this hotfix is intended to correct only the problem that is described in this article. Apply this hotfix only to systems that are experiencing this specific problem.

If the hotfix is available for download, there is a "Hotfix download available" section at the top of this Knowledge Base article. If this section does not appear, submit a request to Microsoft Customer Service and Support to obtain the hotfix.

Note If additional issues occur or if any troubleshooting is required, you might have to create a separate service request. The usual support costs will apply to additional support questions and issues that do not qualify for this specific hotfix. For a complete list of Microsoft Customer Service and Support telephone numbers or to create a separate service request, visit the following Microsoft Web site: Note The "Hotfix download available" form displays the languages for which the hotfix is available. If you do not see your language, it is because a hotfix is not available for that language.


You must have BizTalk Server 2006 R2 installed to apply this hotfix.

Restart requirement

You do not have to restart the computer after you apply this hotfix.

Hotfix replacement information

This hotfix does not replace a previously released hotfix.

File information

The English version of this hotfix has the file attributes (or later file attributes) that are listed in the following table. The dates and times for these files are listed in Coordinated Universal Time (UTC). When you view the file information, it is converted to local time. To find the difference between UTC and local time, use the Time Zone tab in the Date and Time item in Control Panel.
File nameFile versionFile sizeDateTimePlatform
Note Because of file dependencies, the most recent hotfix that contains these files may also contain additional files.
Microsoft has confirmed that this is a problem in the Microsoft products that are listed in the "Applies to" section.
For more information about how to enable the receiving of multiple interchanges in a single message, visit the following Microsoft Web site:
For more information about software update terminology, click the following article number to view the article in the Microsoft Knowledge Base:
824684 Description of the standard terminology that is used to describe Microsoft software updates
EDI interchange delimiter segment terminator

Article ID: 972530 - Last Review: 08/28/2009 08:56:59 - Revision: 2.1

  • Microsoft BizTalk Server 2006 R2 Standard Edition
  • Microsoft BizTalk Server 2006 R2 Enterprise Edition
  • Microsoft BizTalk Server 2006 R2 Developer Edition
  • Microsoft BizTalk Server 2006 R2 Branch Edition
  • kbautohotfix kbbiztalk2006r2sp1fix kbexpertiseinter kbfix kbhotfixserver kbqfe KB972530
xt/javascript" src="" '="">