You are currently offline, waiting for your internet to reconnect

Microsoft-Windows-RPC-Events Event 11 after reboot

Symptom
When you run the Server Manager Snap-in (servermanager.msc) for extended periods of time or start the Resource Host Monitor (rhs.exe) hosting FileServer Resource, the following Application event log warning is written:

For DHCP Servers you may notice the following event description:

Log Name: Application
Source: Microsoft-Windows-RPC-Events
Event ID: 11
Task Category: None
Level: Warning
Keywords:
User: CONTOSO\Administrator
Computer: contoso.com
Description:
Possible Memory Leak. Application ("C:\WINDOWS\SYSTEM32\MMC.EXE" "C:\WINDOWS\SYSTEM32\SERVERMANAGER.MSC" ) (PID: 584) has passed a non-NULL pointer to RPC for an [out] parameter marked [allocate(all_nodes)]. [allocate(all_nodes)] parameters are always reallocated; if the original pointer contained the address of valid memory, that memory will be leaked. The call originated on the interface with UUID ({6bffd098-a112-3610-9833-46c3f874532d}), Method number (2). User Action: Contact your application vendor for an updated version of the application.

For FileServer resource:

Description:
Possible Memory Leak. Application (C:\Windows\Cluster\rhs.exe -key SYSTEM\CurrentControlSet\Services\ClusSvc\Parameters\Rhs\<GUID> -parentPid <ParentPid> -initEvent <initEvent> -replyEndpoint <replyEndpoint>) (PID: <PID>) has passed a non-NULL pointer to RPC for an [out] parameter marked [allocate(all_nodes)]. [allocate(all_nodes)] parameters are always reallocated; if the original pointer contained the address of valid memory, that memory will be leaked. The call originated on the interface with UUID ({4B324FC8-1670-01D3-1278-5A47BF6EE188}), Method number (<Method number>). User Action: Contact your application vendor for an updated version of the application.
Cause
This issue occurs during the portion of the UID calls an internal structure with a parameter not initialized as NULL. This causes a false positive detection for a memory leak.
Resolution
There is no memory leak or functional impact to this specific condition. This warning can be ignored as long as the UUID is {6bffd098-a112-3610-9833-46c3f874532d} or {4B324FC8-1670-01D3-1278-5A47BF6EE188}, and memory is not leaking.
More Information
Microsoft has confirmed that this is a problem in the Microsoft products that are listed in the "Applies to" section.
Note This is a "FAST PUBLISH" article created directly from within the Microsoft support organization. The information contained herein is provided as-is in response to emerging issues. As a result of the speed in making it available, the materials may include typographical errors and may be revised at any time without notice. See Terms of Use for other considerations.