Symptoms

When you use Microsoft BizTalk Server to receive a compressed Applicability Statement 2 (AS2) message, an error message that resembles the following might be logged in the Application log:

Event Type: Error
Event Source: BizTalk Server 2009 EDI
Event Category: None
Event ID: 8133
Description:
The AS2 Decoder encountered an exception during processing. Details of the message and exception are as follows: AS2-From:"<AS2-From party>" AS2-To:"<AS2-To party>" MessageID:"<Message ID>" MessageType: "unknown" Exception:"Decompression failed while processing a compressed AS2 message. Error: Invalid Adler32 checksum encountered."

Note The event source value may vary depending on what version of BizTalk Server you use.

Cause

This issue occurs because the Adler32 checksum value is stored separately in two chunks when you receive a compressed AS2 message. Therefore, BizTalk Server does not read the value correctly.

Resolution

Cumulative update information

BizTalk Server 2006 R2
The hotfix that resolves this issue is included in cumulative update package 4 for BizTalk Server 2006 R2 SP1.

For more information about how to obtain the cumulative update package, click the following article number to view the article in the Microsoft Knowledge Base:


2682056Cumulative update package 4 for BizTalk Server 2006 R2 SP1

BizTalk Server 2010
For more information about how to obtain the cumulative update package, click the following article number to view the article in the Microsoft Knowledge Base:

2497789 Cumulative update package 1 for BizTalk 2010
BizTalk Server 2009
The hotfix that resolves this issue is included in cumulative update package 2 for BizTalk Server 2009.

For more information about how to obtain the cumulative update package, click the following article number to view the article in the Microsoft Knowledge Base:

2497794 Cumulative update package 2 for BizTalk Server 2009

Status

Microsoft has confirmed that this is a problem in the Microsoft products that are listed in the "Applies to" section.

References

For more information about BizTalk Server hotfixes, click the following article number to view the article in the Microsoft Knowledge Base:

2003907 Information about BizTalk Server hotfixes

For more information about the "Invalid Adler32 checksum encountered" error message, visit the following MSDN website:

General information about the "Invalid Adler32 checksum encountered" error message

도움이 더 필요하세요?

더 많은 옵션을 원하세요?

Explore subscription benefits, browse training courses, learn how to secure your device, and more.

Communities help you ask and answer questions, give feedback, and hear from experts with rich knowledge.

이 정보가 유용한가요?

사용 경험에 어떠한 영향을 주었나요?
제출을 누르면 피드백이 Microsoft 제품과 서비스를 개선하는 데 사용됩니다. IT 관리자는 이 데이터를 수집할 수 있습니다. 개인정보처리방침

의견 주셔서 감사합니다!

×