Troubleshooting cluster issue with Event ID 1135

What does this guide do?

Helps you diagnose and resolve Event ID 1135 which may be logged during the startup of the Cluster service in Failover Clustering environment.

Who is it for?

Administrators who help solve Event ID 1135 for the Cluster service.

How does it work?

We’ll take you through a series of troubleshooting steps that are specific to your situation.

Estimated time of completion:

30-60 minutes.

Start Page

Event ID 1135 indicates that one or more Cluster node was removed from the active failover cluster membership. It may be accompanied by the following symptoms 

A validation and the network tests would be recommended as one of the initial troubleshooting steps to ensure there are no configuration issues that might be a cause for problems.


Check if installed the recommended hotfixes

The Cluster service is the essential software component that controls all aspects of failover cluster operation and manages the cluster configuration database. If you see the event ID 1135, Microsoft recommends you to install the fixes mentioned in the below KB articles and reboot all the nodes of the cluster, then observe if issue re-occurs.

Check if the cluster service running on all the nodes

Please follow the following command according to your Windows operation system to validate that cluster service is continuously running and available.

For Windows Server 2008 R2 cluster:

from elevated cmd prompt run: cluster.exe node /stat

For Windows Server 2012\ and Windows Server 2012 R2 cluster:

run PS command: cluster node /status


Is the cluster service continuously running and available on all the nodes?

Start Page

Event ID 1135 indicates that one or more Cluster node was removed from the active failover cluster membership. It may be accompanied by the following symptoms 

A validation and the network tests would be recommended as one of the initial troubleshooting steps to ensure there are no configuration issues that might be a cause for problems.


Check if installed the recommended hotfixes

The Cluster service is the essential software component that controls all aspects of failover cluster operation and manages the cluster configuration database. If you see the event ID 1135, Microsoft recommends you to install the fixes mentioned in the below KB articles and reboot all the nodes of the cluster, then observe if issue re-occurs.

Check if the cluster service running on all the nodes

Please follow the following command according to your Windows operation system to validate that cluster service is continuously running and available.

For Windows Server 2008 R2 cluster:

from elevated cmd prompt run: cluster.exe node /stat

For Windows Server 2012\ and Windows Server 2012 R2 cluster:

run PS command: cluster node /status


Is the cluster service continuously running and available on all the nodes?

Solution for cluster service is failing

If cluster service is failing, troubleshoot using this link: http://blogs.technet.com/b/askcore/archive/2010/06/08/windows-server-2008-and-2008r2-failover-cluster-startup-switches.aspx


Did this solve your problem?

Several scenarios of Event ID 1135

We want you to take a closer look on at the System Event logs on all the nodes of your cluster. Review the Event ID 1135 that you are seeing on the nodes and copy all the instances of this event. This will make it convenient for you to look at them and review.

Event ID 1135Cluster node ‘NODE A’ was removed from the active failover cluster membership. The Cluster service on this node may have stopped. This could also be due to the node having lost communication with other active nodes in the failover cluster. Run the Validate a Configuration wizard to check your network configuration. If the condition persists, check for hardware or software errors related to the network adapters on this node. Also check for failures in any other network components to which the node is connected such as hubs, switches, or bridges.
There are three typical scenarios:

SCENARIO A:

You are looking at all the Events and all the nodes in the cluster are indicating that NODE A had lost communication.

3878_image11
 
3878_image12
 

It could be possible that when you are seeing the system logs on NODE A, it has events for all the remaining nodes in the cluster.

SCENARIO B:

You are looking at the Events on the nodes and let us say that your cluster is dispersed across two sites. NODE A, NODE B and NODE C at Site 1 and NODE D & NODE E at Site 2.

3878_image13
 

On Nodes A,B, and C, you see that the events that are logged are for connectivity to Nodes D & E. Similarly, when you see the events on Nodes D & E, the events suggest that we lost communication with A, B and C.

3878_image14
 

SCENARIO C:

You are looking at the Events on the nodes and you see that the names of the nodes do not tally out with the any particular pattern. Let us say that your cluster is dispersed across two sites. NODE A, NODE B and NODE C at Site 1 and NODE D & NODE E at Site 2.

  • On Node A: You see events for Nodes B, D, E.
  • On Node B: You see events for Nodes C, D, E.
  • On Node C: You see events for Nodes A, B, E.
  • On Node D: You see events for Nodes A, C, E.
  • On Node E: You see events for Nodes B, C, D.
  • Or any other combinations. 

3878_image16
 


Select your scenario:

Solution for scenario A

This quite suggests that at the time of issue, either due to network congestion or otherwise the communication to the NODE A was lost.

You should review and validate the Network configuration and communication issues. Remember to look for issues pertaining to Node A.


Did this solve your problem?

Solution for Scenario B

If you see similar activity, it is indicative that there was a communication failure, over the link that connects these sites. We would recommend that you review the connection across the sites, if this is over a WAN connection, we would suggest that you verify with your ISP about the connectivity.


Did this solve your problem?

Solution for scenario C

Such events are possible when the network channels between the nodes are quite choked and the cluster communication messages are not reaching in a timely manner, making the cluster to feel that the communication between the nodes is lost resulting in the removal of nodes from the cluster membership.


Did this solve your problem?

Review Cluster Networks

We would recommend that you review you Cluster Networks by checking the following three option one by one to continue this troubleshooting guide.


What do you want to do next?

Check for Antivirus Exclusion

Exclude the following file system locations from virus scanning on a server that is running Cluster Services:

  • The path of the FileShare Witness.
  • The %Systemroot%\Cluster folder.
Configure the real-time scanning component within your antivirus software to exclude the following directories and files:
  • Default virtual machine configuration directory (C:\ProgramData\Microsoft\Windows\Hyper-V)
  • Custom virtual machine configuration directories
  • Default virtual hard disk drive directory (C:\Users\Public\Documents\Hyper-V\Virtual Hard Disks)
  • Custom virtual hard disk drive directories
  • Custom replication data directories, if you are using Hyper-V Replica
  • Snapshot directories
  • mms.exe (Note: This file may have to be configured as a process exclusion within the antivirus software.)
  • Vmwp.exe (Note: This file may have to be configured as a process exclusion within the antivirus software.)
Additionally, when you use Live Migration together with Cluster Shared Volumes, exclude the CSV path "C:\Clusterstorage" and all its subdirectories.
If you are troubleshooting failover issues or general problems with a Cluster services and antivirus software is installed, temporarily uninstall the antivirus software or check with the manufacturer of the software to determine whether the antivirus software works with Cluster services. Just disabling the antivirus software is insufficient in most cases. Even if you disable the antivirus software, the filter driver is still loaded when you restart the computer.

Did this solve your problem?
Check for Network Port Configuration in Firewall

The Cluster service controls server cluster operations and manages the cluster database. A cluster is a collection of independent computers that act as a single computer. Managers, programmers, and users see the cluster as a single system. The software distributes data among the nodes of the cluster. If a node fails, other nodes provide the services and data that were formerly provided by the missing node. When a node is added or repaired, the cluster software migrates some data to that node.

System service name: ClusSvc

 Application Protocol Ports
 Cluster ServiceUDP  3343
 Cluster Service TCP 3343 (This port is required during a node join operation.)
 RPC TCP 135
 Cluster Admin UDP 137
 Kerberos UDP\TCP 464*
 SMB TCP 445
 Randomly allocated high UDP ports** UDPRandom port number between 1024 and 65535
 Random port number between 49152 and 65535*** 

Note:

Additionally, for successful validation on Windows Failover Clusters on Windows Server 2008 and above, allow inbound and outbound traffic for ICMP4, ICMP6. 

* For more information see, Creating a Windows Server 2012 Failover Cluster Fails with Error 0xc000005e http://support.microsoft.com/kb/2830510

**For more information about how to customize these ports, see "Remote Procedure Calls and DCOM" in the “References" section in KB832017

***This is the range in Windows Server 2012, Windows 8, Windows Server 2008 R2, Windows 7, Windows Server 2008, and Windows Vista.

Besides,please run the following command to check for Network Port Configuration in Firewall. For example: This command helps determine port 3343 available\open used for Failover Cluster:

netsh advfirewall firewall show rule name="Failover Clusters (UDP-In)" verbose


Did this solve your problem?

Run the Cluster Validation report for any errors or warnings

The cluster validation tool runs a suite of tests to verify that your hardware and settings are compatible with failover clustering.

Follow these instructions:

  1. Run the Cluster Validation report for any errors or warnings.Check this blog for more details.
    3878_image4
     
  2. Verify for warnings and errors for Networks with the article below: http://technet.microsoft.com/en-us/library/cc771323.aspx
    3878_image5
     
    3878_image6
     


What do you want to do next?

Check the List Network Binding Order

This test lists the order in which networks are bound to the adapters on each node.

The Adapters and Bindings tab lists the connections in the order in which the connections are accessed by network services. The order of these connections reflects the order in which generic TCP/IP calls/packets are sent on to the wire.

Follow the below steps to change the binding order of network adapters

  1. Click Start, click Run, type ncpa.cpl, and then click OK. You can see the available connections in the LAN and High-Speed Internet section of the Network Connections window.
  2. On the Advanced menu, click Advanced Settings, and then click the Adapters and Bindings tab.
  3. In the Connections area, select the connection that you want to move higher in the list. Use the arrow buttons to move the connection. As a general rule, the card that talks to the network (domain connectivity, routing to other networks, etc should be the first bound (top of the list) card.

Cluster nodes are multi-homed systems. Network priority affects DNS Client for outbound network connectivity. Network adapters used for client communication should be at the top in the binding order. Non-routed networks can be placed at lower priority. In Windows Server 2012 and Windows Server2012 R2, the Cluster Network Driver (NETFT.SYS) adapter is automatically placed at the bottom in the binding order list.


Did this solve your problem?

Check the Validate Network Communication

Latency on your network could also cause this to happen. The packets may not be lost between the nodes, but they may not get to the nodes fast enough before the timeout period expires.

This test validates that tested servers can communicate with acceptable latency on all networks.

For Example: Under Validate Network Communication, you may see following messages for network latency issues.

Succeeded in pinging network interface node003.contoso.com IP Address 192.168.0.2 from network interface node004.contoso.com IP Address 192.168.0.3 with maximum delay 500 after 1 attempt(s).Either address 10.0.0.96 is not reachable from 192.168.0.2 or the ping latency is greater than the maximum allowed 2000 ms This may be expected, since network interfaces node003.contoso.com - Heartbeat Network and node004.contoso.com - Production Network are on different cluster networksEither address 192.168.0.2 is not reachable from 10.0.0.96 or the ping latency is greater than the maximum allowed 2000 ms This may be expected, since network interfaces node004.contoso.com - Production Network and node003.contoso.com - Heartbeat Network for MSCS are on different cluster networks
For multi-site cluster you may want to increase the time-out values.

Check with ISP for any WAN connectivity issues.


What other issues are you experiencing?


Network packets lost between nodes
  1. Check Packet loss using Perfmon
    If the packet is lost on the wire somewhere between the nodes, then the heartbeats will fail. We can easily find out if this is a problem by using Performance Monitor to look at the “Network Interface\Packets Received Discarded” counter. Once you have added this counter, look at the Average, Minimum and Maximum numbers and if they are any value higher than zero, then the receive buffer needs to be adjusted up for the adapter.
    3878_image17
     
    If you are experiencing network packet lost on VmWare virtualization platform, see the Cluster installed in the VmWare virtualization platform section.
  2. Upgrade the NIC drivers
    This issue can occurs due to outdated NIC drivers\Integration Components (IC)\VmTools or faulty NIC adapters.
    If there are network packets lost between nodes on Physical machines,please have your network adapter driver updates. Old or out of date network card drivers and/or firmware.
    At times, a simple misconfiguration of the network card or switch can also cause loss of heartbeats.

Did this solve your problem?




Cluster installed in the VmWare virtualization platform

Verify vmware adapter issues in case of VMware environment

This issue may occur if the packets are dropped during high traffic bursts.

Ensure that there is no traffic filtering occurring (for example, with a mail filter). After eliminating this possibility, gradually increase the number of buffers in the guest operating system and verify.

To reduce burst traffic drops, follow these steps:

  1. Open Run box by using Windows Key + R .
  2. Type devmgmt.msc and press Enter.
  3. Expand Network adapters
  4. Right-click vmxnet3 and click Properties.
  5. Click the Advanced tab.
  6. Click Small Rx Buffers and increase the value. The default value is 512 and the maximum is 8192.
  7. Click Rx Ring #1 Size and increase the value. The default value is 1024 and the maximum is 4096.

Check the following URLs to verify vmware adapter issues in case of VMware environment:

http://blogs.technet.com/b/askcore/archive/2013/06/03/nodes-being-removed-from-failover-cluster-membership-on-vmware-esx.aspx

http://kb.vmware.com/selfservice/microsites/search.do?language=en_US&cmd=displayKC&externalId=2039495

Noticed any Network congestion

Network congestion can also cause network connectivity issues.

Verify that your network is configured as per MS and vendor recommendations:

Review Configuring Windows Failover Cluster Networks http://blogs.technet.com/b/askcore/archive/2014/02/20/configuring-windows-failover-cluster-networks.aspx

Check the network configuration

If it still does not work please check if you have seen partitioned network in cluster GUI or you have NIC teaming enabled on the heartbeat NIC.


What is the issue you are facing?

Partitioned network in cluster GUI

If you see partitioned network in cluster GUI, you can follow this blog article to troubleshoot the issue: http://blogs.technet.com/b/askcore/archive/2011/08/08/partitioned-cluster-networks.aspx


Did this solve your problem?

Upgrade the NIC drivers

This issue can occurs due to outdated NIC drivers or faulty NIC adapters.

If there are network packets lost between nodes on Physical machines,please have your network adapter driver updates. Old or out of date network card drivers and/or firmware.

At times, a simple misconfiguration of the network card or switch can also cause loss of heartbeats.


Did this solve your problem?

Check the network configuration

If it still does not work please check if you have seen partitioned network in cluster GUI or you have NIC teaming enabled on the heartbeat NIC.


What is the issue you are facing?

NIC teaming enabled on the heartbeat NIC

If you have NIC teaming enabled on the heartbeat NIC, please check Teaming software functionality as per teaming vendor’s recommendation.


Did this solve your problem?

Congratulations!

Your cluster issue is resolved.

Sorry

It appears that we are unable to resolve your issue by using this guide. For more help resolving this issue please see our TechNet support forum or contact Microsoft Support.

Noticed any Network congestion

Network congestion can also cause network connectivity issues.

Verify that your network is configured as per MS and vendor recommendations:

Review Configuring Windows Failover Cluster Networks http://blogs.technet.com/b/askcore/archive/2014/02/20/configuring-windows-failover-cluster-networks.aspx

Check the network configuration

If it still does not work please check if you have seen partitioned network in cluster GUI or you have NIC teaming enabled on the heartbeat NIC.


What is the issue you are facing?