SYMPTOMS

You receive a "Run-time error "-2147417848 (80010108) Automation error: The object invoked has disconnected from its clients" error message when youopen Parent.exe after you install theCode Jock command bars control.


CAUSE

The incorrect Commandbars.ocx file is in use.


RESOLUTION

1.Copy the Commandbars.ocx file from the Solomon 6.0 CD tothe C:\%windir%\System32 folder.


2. Copy the .lic file from the installationpurchased from Code Jock to the C:\%windir%\System32 folder.


3. Register the Commandbars.ocx file from step 1 in the System32 folder.

This article was TechKnowledge Document ID:137526

The issue that is described in the Symptoms section does not apply to Microsoft Dynamics SL 7.0.